Skip to content

Worked examples: the OpenAPI schema and MQTT discovery

Developers Guide · REST API and OpenAPI · MQTT

Two ways for another program to work with the Bridge, end to end:

  1. REST, from the OpenAPI schema: discover what the API offers, then read and control your aGate with plain HTTP.
  2. MQTT, through Home Assistant discovery: read the aGate's values and send commands on a broker, the same way Home Assistant does.

Where the output on this page came from

Every command and response below was run on 2026-11-19 against Bridge 0.5.53 (/api/version reported source_sha unknown, a build from a git archive of the docs/use-cases branch). It ran as a fresh pip install on macOS, with Security on as for any new install, pointed at the library's emulator (franklinwh-direct-connect emulate --seed 7) and a throwaway MQTT broker, all on loopback. The values are synthetic. The emulator stores a mode write and reads it back, so a read-back here does not prove what a real aGate does. That the aGate applies a local mode write is recorded as hardware-verified in the README. Hosts, serials and tokens are replaced with placeholders.


1. REST, from the OpenAPI schema

Before you start: a token and the certificate

A new install has Security on. API calls then go to the HTTPS port with a token; the plain port redirects there (307). As an admin, in Settings → Admin → Security:

  1. Accounts → add an account with the role api (no password). It can read everything and send battery commands.
  2. API tokens → + New token for that account. Copy the token (it starts fwhdc_); it is shown once.
  3. Download certificate, so your client can check the Bridge's self-signed certificate rather than skip the check.

To read the schema, also make a token for a viewer account (it needs a password of 8 characters or more). See the warning below.

export BRIDGE=https://<bridge-host>:8102
export TOKEN=fwhdc_…            # the api account's token
export VIEW_TOKEN=fwhdc_…       # a viewer account's token, for the schema
export CA=franklinwh-bridge.crt # the downloaded certificate

An api token can't read the schema yet

GET /openapi.json, /docs and /redoc answer 403 "Your role (api) can't do this." to an api token (#781). The role rules treat every path outside /api/ as a web page, and api accounts have no pages (security.required()). A viewer token, or a signed-in browser, gets them. Use a viewer token to fetch the schema and the api token for everything else.

With Security off (an upgraded install), leave out the token and the certificate and use the plain port: export BRIDGE=http://<bridge-host>:8101.

Step 1: fetch the schema

curl -s --cacert "$CA" -H "Authorization: Bearer $VIEW_TOKEN" \
     "$BRIDGE/openapi.json" -o openapi.json

jq '{title: .info.title, version: .info.version, openapi,
     paths: (.paths | length),
     operations: ([.paths[] | keys[] | select(. != "parameters")] | length)}' openapi.json
{
  "title": "franklinwh-direct-connect-bridge",
  "version": "0.5.53",
  "openapi": "3.1.0",
  "paths": 277,
  "operations": 315
}

The same token opens Swagger UI at $BRIDGE/docs and ReDoc at $BRIDGE/redoc in a browser that is signed in.

Step 2: find an endpoint and what it takes

Search the paths:

jq -r '.paths | to_entries[] | select(.key | test("summary")) | .key as $p
       | .value | to_entries[] | "\(.key | ascii_upcase) \($p)  \(.value.summary)"' openapi.json
GET /api/summary  Api Summary
GET /api/gateways/{gw_id}/summary  Api Gateway Summary

Look at what a write needs, here the operating mode:

jq '.paths["/api/mode"].post | {parameters: [.parameters[] | {name, in, required}],
     body: .requestBody.content["application/json"].schema}' openapi.json
jq -c '.components.schemas.ModeReq' openapi.json
{
  "parameters": [{ "name": "gateway", "in": "query", "required": false }],
  "body": { "$ref": "#/components/schemas/ModeReq" }
}
{"properties":{"mode":{"type":"string","title":"Mode"},"confirm":{"type":"boolean","title":"Confirm","default":false}},"type":"object","required":["mode"],"title":"ModeReq"}

Any OpenAPI 3.1 tool can read the same file, for example to generate a client.

Step 3: find your gateway and read it

curl -s --cacert "$CA" -H "Authorization: Bearer $TOKEN" "$BRIDGE/api/gateways" \
  | jq -c '.[] | {id, label, is_default, publish_ha}'
{"id":"<gateway-id>","label":"<label>","is_default":true,"publish_ha":true}
export GW=<gateway-id>
curl -s --cacert "$CA" -H "Authorization: Bearer $TOKEN" "$BRIDGE/api/summary?gateway=$GW" \
  | jq '{ok, cached, soc: .power.soc, solar_w: .power.solar_w, battery_w: .power.battery_w,
         grid_w: .power.grid_w, load_w: .power.load_w,
         mode: (.mode.modes[] | select(.active) | .name), latency_ms}'
{
  "ok": true,
  "cached": true,
  "soc": 26.6,
  "solar_w": 0.0,
  "battery_w": 828.3,
  "grid_w": 276.1,
  "load_w": 1104.4,
  "mode": "Time-of-Use",
  "latency_ms": 1.2
}

/api/summary is the poller's cached copy ("cached": true), so reading it costs the aGate nothing. Name the gateway on every call that acts on an aGate.

Step 4: change something, safely

A write that changes the gateway needs "confirm": true. Without it the Bridge refuses:

curl -s --cacert "$CA" -H "Authorization: Bearer $TOKEN" -H 'content-type: application/json' \
     -d '{"mode":"Self-Consumption"}' "$BRIDGE/api/mode?gateway=$GW"
HTTP 428  {"detail":"'set operating mode' changes the physical gateway — re-send with confirm=true."}
curl -s --cacert "$CA" -H "Authorization: Bearer $TOKEN" -H 'content-type: application/json' \
     -d '{"mode":"Self-Consumption","confirm":true}' "$BRIDGE/api/mode?gateway=$GW"
HTTP 200  {"ok":true,"result":0,"current_id_before":29287,"current_id_after":85232}

The summary showed the new mode after the next poll, about 20 seconds later here.

Not every write asks for confirm

Battery force and release (POST /api/battery/command), POST /api/dispatch, smart circuits, reserve SoC and creating a schedule are not confirm-gated. Read Write safety before you automate a write.

What a refusal looks like

All observed in the same run:

Request Answer
A wrong or expired token 401 "Invalid or expired API token."
A viewer token sending a mode change 403 "Your role (viewer) can't do this."
An unknown gateway id 404 "unknown gateway 'nope'"
A mode change without confirm 428, as above

The same in Python

Standard library only, run against the same Bridge:

"""Read the Bridge's live summary with an API token (standard library only)."""
import json, os, ssl, urllib.request

BRIDGE = os.environ["BRIDGE"]             # e.g. https://bridge.local:8102
TOKEN = os.environ["BRIDGE_TOKEN"]        # fwhdc_…
CA = os.environ.get("BRIDGE_CA", "franklinwh-bridge.crt")

ctx = ssl.create_default_context(cafile=CA)

def get(path):
    req = urllib.request.Request(BRIDGE + path, headers={"Authorization": f"Bearer {TOKEN}"})
    with urllib.request.urlopen(req, context=ctx) as r:
        return json.load(r)

for gw in get("/api/gateways"):
    s = get(f"/api/summary?gateway={gw['id']}")
    p = s["power"]
    mode = next(m["name"] for m in s["mode"]["modes"] if m["active"])
    print(f"{gw['label']}: SoC {p['soc']}%  solar {p['solar_w']} W  "
          f"battery {p['battery_w']} W  grid {p['grid_w']} W  mode {mode}")
<label>: SoC 26.5%  solar 0.0 W  battery 793.3 W  grid 264.4 W  mode Time-of-Use

2. MQTT, through Home Assistant discovery

With MQTT on, the Bridge publishes each aGate to the broker as a Home Assistant device. Home Assistant builds the device from the discovery messages; any other MQTT client can read the same topics and send the same commands. No token is involved: access is whatever your broker allows.

Step 1: see what is published

mosquitto_sub -h <broker> -u <user> -P <password> -v -t 'homeassistant/#' -t 'franklinwh-local/#'

In the run, the broker held 66 discovery configs (53 sensors, 8 binary sensors, 1 select, 4 switches) and these other topics. <node> is the gateway's serial, lower-cased:

Topic Retained What it carries
franklinwh-local/<node>/state yes One JSON object with every value (75 keys in the run)
franklinwh-local/<node>/availability yes online or offline
franklinwh-local/<node>/alerts yes {"problem":false,"level":"ok","open":0,"alerts":[]}
franklinwh-local/<node>/control/<key>/set no Commands to the Bridge
franklinwh-local/fwh_dc_bridge/heartbeat yes The Bridge's last heartbeat time
franklinwh-local/fwh_dc_bridge/version yes The Bridge version, install type and library versions
franklinwh-local/fwh_dc_bridge/alerts yes Bridge-wide alerts, same shape as above

The controls are the Operating Mode select, Go Off-Grid, and one switch per smart circuit.

Step 2: read a discovery config and the state

The discovery config for State of Charge, on homeassistant/sensor/<node>/soc/config:

{
  "name": "State of Charge",
  "unique_id": "franklinwh_<node>_soc",
  "object_id": "franklinwh_<node>_soc",
  "state_topic": "franklinwh-local/<node>/state",
  "value_template": "{{ value_json.soc }}",
  "availability_topic": "franklinwh-local/<node>/availability",
  "device": {
    "identifiers": ["franklinwh_<node>"],
    "name": "FranklinWH Direct <last 8 of serial>",
    "manufacturer": "FranklinWH Technologies Co., Ltd",
    "model": "aGate",
    "sw_version": "Direct Connect Bridge v0.5.53",
    "hw_version": "aGate <firmware>",
    "serial_number": "<serial>"
  },
  "unit_of_measurement": "%",
  "device_class": "battery",
  "state_class": "measurement",
  "suggested_display_precision": 1
}

Each config points at the shared state topic and picks its own field with value_template. A few fields of the state, on franklinwh-local/<node>/state:

{
  "soc": 26.7,
  "solar_w": 0.0,
  "battery_w": 829.5,
  "grid_w": 276.5,
  "load_w": 1106.0,
  "mode": "Self-Consumption",
  "run_status_desc": "Discharging",
  "off_grid": false,
  "battery_status": "discharging",
  "solar_today_kwh": 12.93,
  "load_today_kwh": 12.03,
  "circuit_1_on": true
}

To follow one value from a script, subscribe to the state topic and read the key:

mosquitto_sub -h <broker> -u <user> -P <password> -t 'franklinwh-local/<node>/state' \
  | jq --unbuffered '{soc, solar_w, mode}'

Step 3: send a command

The Operating Mode select's config names its command topic and the options it accepts:

{"name":"Operating Mode",
 "command_topic":"franklinwh-local/<node>/control/operating_mode/set",
 "options":["Time-of-Use","Self-Consumption","Emergency Backup"],
 "value_template":"{{ value_json.mode }}"}

Publish one of the options to it:

mosquitto_pub -h <broker> -u <user> -P <password> \
  -t 'franklinwh-local/<node>/control/operating_mode/set' -m 'Time-of-Use'

In the run, the state topic showed "mode": "Time-of-Use" about 10 seconds later. The smart circuit and Go Off-Grid switches take ON and OFF.

MQTT commands have no confirm step

Unlike POST /api/mode, a command on MQTT is carried out at once. Anything that can publish to your broker can change the mode, switch circuits and take the site off-grid. Give the broker a username and password, and don't expose it outside your network.

Step 4: use it in Home Assistant

Home Assistant creates the device and its entities from the discovery configs, with no YAML. Use them like any other entity. This automation puts the aGate in Self-Consumption at 21:00. Replace the entity id with yours, from Settings → Devices & services → MQTT → FranklinWH Direct …:

automation:
  - alias: "aGate: Self-Consumption at night"
    triggers:
      - trigger: time
        at: "21:00:00"
    actions:
      - action: select.select_option
        target:
          entity_id: select.franklinwh_direct_operating_mode   # replace with yours
        data:
          option: "Self-Consumption"

This automation was not run in Home Assistant for this page. The select publishes the option to the command topic above, as in Step 3.


Which one to use

REST MQTT
Discover what exists The OpenAPI schema The discovery configs
Read Any time, on request Every poll, pushed to you
Access control Accounts, roles and tokens Your broker's own users
Write safety confirm on consequential writes None