0.5.17 — 2026-10-27¶
Fixed¶
-
Dashboard Run status shows the state that matters (#313). It showed only the aGate's battery run status, so it read "Standby" in Debug Mode and kept saying "Discharging" during VPP. It now shows the first of these that applies: Debug Mode, Off-grid, VPP, Reconnecting, then the battery run status. Hover it to see the source. In the top bar the FORCE chip is now VPP: the aGate reports a force from this bridge as VPP too, like the FranklinWH app. SUPPORT SESSION is now DEBUG MODE. Debug Mode is still recognised only from run status 8. Reading the aGate's Debug Mode setting comes with #311. Known gap: a WSet force (Model 704) is no longer shown apart from VPP; they are different states, and #333 brings FORCE back.
-
After a reconnect, the aGate's all-zero answers no longer show or record as 0 W (#309). For a minute or two after a reboot or a lost connection the aGate reports 0 for the battery charge and every power flow. The dashboard showed 0 W, history recorded it and Home Assistant received it. Those values now read "--", the dashboard says "aGate reconnecting — no readings yet", nothing is recorded or sent to Home Assistant, and the log says when the zeros start and when real readings return. Per-aPower values from the same answer were real and are still shown.