0.5.50 — 2026-11-17¶
Everything merged since 0.5.49, by area:
- Scheduler: Smart Circuits, Generator and V2L sensor groups (on/off, power, energy, generator state), greyed out when not installed.
- Home Assistant: the Dashboard card uses Home Assistant's real entity ids; the "Bridge entities in Home Assistant" check works with thousands of leftovers.
- Dashboard: the State of Charge and Energy cards reflow instead of cutting text off.
- All gateways: the site SoC is weighted by battery capacity; Derive from aPower and Sync from gateway name the gateway.
- Troubleshoot: Reconnect to Wi-Fi runs when pressed; the steps fit what the bridge sees.
Added¶
- Scheduler: Smart Circuits, Generator and V2L sensor groups (#698). Each smart
circuit's on/off state (
circuit.N.on), named as your aGate names it (Smart circuit 1 (Pool pump): on), and its name for messages; the generator's energy today; the V2L car switch's enable flag; and whether a generator and V2L are installed, as System Setup has them. All come from the existing poll, with no extra aGate reads. On/off works as a trigger with Always (sensor-driven) and a condition such ascircuit.1.on == 1An accessory the schedule's gateway doesn't have stays listed but is greyed out, marked (not installed) (guide). - Scheduler: smart circuit, V2L and generator readings (#698). Every 60 seconds the poll also reads the smart-circuit and V2L meter and the generator in the same aGate session: each circuit's power and energy today, the installed circuit count, the V2L power and lifetime energy, and the generator's enabled flag, state (Standby, Running, Cooldown, Fault) and rated power. A read that fails leaves them without a value; the poll carries on (guide).
Changed¶
- Troubleshoot: Reconnect to Wi-Fi runs when pressed; it no longer asks you to type RECONNECT first (guide).
- Troubleshoot: the Steps fit what the bridge sees. "Check the aGate is powered" shows only when it answers nowhere, not while it is on your LAN or online via 4G; with the aGate online there are no steps (guide).
- Settings: Derive from aPower says which gateway its aPower model and count were read from, and Sync from gateway names the gateway it reads (#362) (guide, location).
Fixed¶
- All gateways: the site total's SoC was a plain average (#358). A full gateway with two aPowers and an empty one with one aPower showed 50%; the site holds two thirds. It is now weighted by each gateway's battery capacity (aPower count × usable kWh). Until a gateway's aPowers have been read it stays the plain average, marked "avg" (guide).
- Dashboard: the Battery State of Charge and Energy cards cut text off or ran past their edge when narrow, such as a window about 1024–1200 px wide with the sidebar open (#370). State of Charge now puts Reserved, Mode, Battery and Run status under the ring, and wraps rather than truncating; Energy shows one column when two don't fit (guide).
- Setup check Bridge entities in Home Assistant said "Could not be checked" when Home Assistant held many leftover entities (about 2,600): the answer was over Home Assistant's 256 KiB template limit. It now counts per device, so it works however many there are (#445, guide).
- Home Assistant → Published by bridge → Dashboard card found none of the bridge's
entities: Home Assistant names them after the device (
sensor.franklinwh_direct_<last 8 of serial>_state_of_charge), and the card looked for ids built from what the bridge publishes. It now asks Home Assistant for the ids of this gateway's device, so the card uses the real ones. The four binary sensors are looked up as binary sensors (#689, guide). - Dashboard card: says in one line what it is, numbers the steps to paste it, and a failure says in plain words what to check; entities left out are listed by name (#689, guide).