Home Assistant control gap: Direct Connect REST vs Direct MQTT vs FWHAI vs Modbus Bridge

Scope. Written 2026-10-16. Compares FranklinWH Direct Connect Bridge 0.4.5 (main at the docs(backlog): RESEARCH-HA-CONTROL-GAP commit), FWHAI 0.6.80 and the Modbus Bridge 0.2.6. Direct REST is every @app.get/post/put/patch/delete("/api/...") in src/franklinwh_direct_connect_bridge/app.py (195 decorated routes: 103 GET, 62 POST, 13 PUT, 7 PATCH, 10 DELETE, plus the /api/cmd/{name} GET reads registered in a loop at runtime). Direct MQTT is publish/entities.py (ENTITIES, CONTROLS). Device limits come from docs/API_COMPARISON.md, docs/LOCAL_ONLY_CAPABILITIES.md, docs/METRICS_GAP_ANALYSIS.md, docs/OFFGRID_DESIGN.md. The agreed direction is docs/MQTT_CONTROLS_PLAN.md (C1 shipped in 0.4.5; C2 reserve via cloud; C3 grid limits not in HA; C4 battery command; off-grid not in HA). FWHAI and Modbus Bridge entities come from Home Assistant MQTT diagnostics exports for one AU aGate (one site, one firmware), taken from discovery_data.payload and device.entities. Producers were separated by device.sw_version (… (FHAI: v0.6.80) vs Modbus Bridge v0.2.6). Source caveat: the export named for this task (mqtt-…-FranklinWH Cloud <SERIAL>-…-2.json, 14:20) contains 90 entities, all FWHAI. It has no Modbus Bridge entities. The Modbus Bridge 0.2.6 entities (65) are taken from the sibling export of the same HA device at 13:10 the same day. That export's FWHAI 90-entity set is identical to the -2 file. Only names, domains and discovery shape are used here. No states, serials or addresses.

Legend. R read · W write (needs allow_writes, 403 otherwise) · W+confirm also needs confirm=true (_guard_consequential, 428 otherwise) · W via cloud needs cloud credentials (_require_cloud, 503 without them) · W via Modbus goes over SunSpec Modbus, not the local sendMqtt API. Most /api/cloud/* routes are local reads re-shaped to cloud JSON (cloud_compat). They do not need the cloud. Only POST /api/cloud/reserve does.

§1 Capability matrix

Capability Direct REST Direct MQTT FWHAI MQTT (name, domain) Modbus Bridge MQTT Local channel can do it? Proposed home
Monitoring sensors
SoC, grid/solar/battery/load W R (/api/power, /api/cloud/stats, /api/energy/flow) yes (5 power sensors + SoC) Not in the 0.6.80 export. The 0.6.76 export (15 Oct) had State of Charge, Grid Power, Solar Power, Battery Power, Home Load (sensor) State of Charge, Grid Power, Solar Power, Battery Power, Home Load, PV Total Power (sensor) yes, 1301 shipped
Daily energy (solar, grid in/out, battery chg/dis, load) R (/api/power) yes (6, total_increasing) Daily Solar Energy, Daily Grid Import/Export, Daily Battery Charge/Discharge (sensor). No daily load Grid Import/Export Energy, Battery Energy Charged/Discharged, Solar Energy Total/Proximal (lifetime, inferred from names) yes, 1301 shipped
Generator power R (/api/generator, /api/power) yes Generator Power (sensor) — yes shipped
Run status / battery state R (run_status_desc in poll) yes, but run_status is the raw number Battery Run Status (enum sensor), Runtime Mode Battery State, Inverter State yes C1 planned the text, but 0.4.5 still publishes the raw value (open)
Ambient temperature R yes Not in 0.6.80 export (0.6.76: Ambient Temperature) Ambient Temperature, Cabinet Temperature yes shipped
Relays (grid 1/2, PV 1/2, generator, black start, aPbox) R (/api/solar, /api/cloud/power-info from 1710) no Grid Relay 1/2, Solar PV Relay 1/2, Generator Relay, Black Start Relay, aPowerBox Relay (binary_sensor) — yes, 1710 / 1707 new item (read-only sensors)
Grid connection status R (/api/grid) no Grid Status (enum: Connected / Outage / SimulatedOffGrid / NotGridTied) Grid Connection yes new item (read-only sensor)
Operating mode and reserves
Operating mode set W+confirm (POST /api/mode, POST /api/cloud/set-mode) yes (select Operating Mode, no confirm) Not in the 0.6.80 export (0.6.76: select Operating Mode, 3 options) Operating Mode (select: Emergency Backup / Self-Consumption / TOU) yes, 1727, hardware-verified (METRICS_GAP_ANALYSIS) shipped. The HA select bypasses confirm (see §3)
Reserve SoC read (per mode) R (/api/cloud/reserves, /api/cloud/mode, local 1405/mode_soc) no Emergency Backup Reserved SOC (sensor) Active Reserve SOC (sensor) yes (read) C2 (state source)
Reserve SoC write, Self / TOU W via cloud (POST /api/cloud/reserve, provider FWHAI REST, then the franklinwh-cloud lib) no Battery Self-Consumption SOC, Battery TOU Reserved SOC (number 0–100 %, step 1) Self-Consumption Reserve SOC, TOU Reserve SOC (number 0–100 %, step 1) discarded: 1405 is accepted and dropped (API_COMPARISON, LOCAL_ONLY). Modbus 15508 "for Self if installer-unlocked" (LOCAL_ONLY) C2, only when the cloud provider is configured
Smart circuits
Circuit on/off with state W (POST /api/circuits/{n}/power, POST /api/cloud/smart-circuit/state) yes (switch Smart Circuit 1–3, state from 1409 since 0.4.5) Circuit 1, <circuit name> (switch; one per configured circuit) — yes, 1409, live-verified 2026-08-08 shipped (C1)
Circuit power / daily energy R (/api/circuits, /api/circuits/meter 1411) no Circuit 1 Power, Circuit 1 Daily Energy, plus the same pair per named circuit (sensor) — yes, 1411 new item (read-only sensors)
Circuit schedule W (PUT /api/circuits/{n}/schedule, returns discarded: true) no — — discarded (live-tested 2026-09-14, three payload shapes) not possible locally
Battery command / dispatch
Force charge / discharge / standby / release, power W/%, duration, target SoC W via Modbus (POST /api/battery/command: staged slugs plus battery_command; POST /api/dispatch delegates to Modbus Bridge REST or the franklinwh-modbus lib). Status via GET /api/battery/command no Dispatch Action (select: Idle / Charge / Discharge / Stop), Dispatch Method (select: Cloud TOU), Dispatch Power (number 0.1–5.0 kW, 0.1), Dispatch Duration (number 5–480 min, 5), Dispatch Target SOC (number 20–100 %, 5) Battery Command (select: Not Active / Force Charge / Force Discharge / Force Standby / Release), Command Power (number 0–5000 W, 100), Command Power % (0–100, 5), Command Duration (0–7200 s, 60), Target SoC (0–100 %, 5) no local cmdType. 1823/1825 undecoded, UNCONFIRMED (API_COMPARISON). Possible over Modbus WSet (704) or cloud ForceMixin (not wired) C4
Dispatch feedback R (GET /api/battery/command: active, remaining_s, state, max W) no Active Dispatch, Dispatch Status (enum: Idle / Charging / Discharging / Stopping / Error), Dispatch Start / End / Remaining (sensor) Last Command Result, Command Elapsed Time, Power Setpoint, Power Setpoint %, WSet Mode, WSet Enabled (binary_sensor), HW Revert Timer / Remaining, SW Watchdog Remaining, Control Mode n/a (bridge state plus Modbus reads) C4 (status, active command, last result)
Max charge / discharge rate R (/api/grid, from Modbus SunSpec 702) no Max Charge Power, Max Discharge Power (sensor, kW) Max Charge Rate, Max Discharge Rate (sensor, kW) 1701 fhpRatePower reads 0 on this firmware (/api/grid docstring). Modbus 702 needed C4 (sizing the power number)
TOU preset dispatches / tariff now/next R (/api/cloud/tou from 1726/1408). Bridge-side /api/schedules* engine no TOU Preset Dispatches (select, 11 options), TOU Dispatch Now / Next / Next Start / Next End / Remaining, TOU Dispatch Tariff Now / Next (enum) — TOU schedule read yes. FWHAI presets are its own engine (METRICS_GAP_ANALYSIS §D) not in plan (new item if wanted, read-only)
Grid limits
Grid import / export limit, export enable, PCS discharge W+confirm (POST /api/grid/limits, 1701 RMW, docstring "UNVERIFIED local write", dry_run supported). Read via GET /api/grid no Grid Import Limit, Grid Export Limit (number 0–100 kW, 0.1), Grid Import Unlimited, Grid Export Unlimited (switch) — unknown: unverified local write. Cloud read+write exists (set_power_control_settings, LOCAL_ONLY §6) not in HA per owner (C3 dropped). Read-only limit sensors would be a new item
Off-grid
Go off-grid / reconnect W+confirm (POST /api/offgrid, 1723). POST /api/cloud/grid-status needs confirm too since 0.4.6 (GHSA-7jmj-vj3g-q2m3) no Off-Grid Mode (select: On-Grid / Off-Grid) — yes, 1723. Requested-island measured live 2026-10-15 (OFFGRID_DESIGN) not in HA per owner
Generator
Generator enable / mode / windows / exercise / SoC thresholds W (PUT /api/generator/enable, POST /api/generator/mode [409 if no generator; "unexercised on real generator hardware"], PUT /api/generator/window/{n}, /exercise, /soc). R /api/generator, /raw no Generator Enabled (binary_sensor, read only) — yes. Windows, exercise and SoC thresholds hardware-verified 2026-09-14 (LOCAL_ONLY §3). Mode write not exercised with a generator new item (no plan). Read-only enable sensor would be cheap
Storm / emergency backup
Emergency backup duration / resume mode — (/api/cloud/set-mode accepts reqbackupForeverFlag, reqnextWorkMode, reqdurationMinutes but reports them in not_applied_locally) no Emergency Backup Duration (number 30–4320 min, 30), Emergency Backup Duration Type (select: Indefinite / 1–3 Days / Customize), Emergency Backup Resume Mode (select) — no: cloud-only per the set-mode docstring not possible locally
Storm hedge — no Storm Hedge (select: Disabled / Enabled), Storm Decision Strategy (select), Storm Backup Lead Time (number 0–330 min, 30) — no: FWHAI's own engine plus a weather feed (LOCAL_ONLY, METRICS_GAP_ANALYSIS §D) not possible locally
Locks / other
Control locks — (nearest: allow_writes setting plus per-call confirm) no Control Lock, Lock Battery Dispatch, Lock Grid Disconnect, Lock Operating Mode (switch, config) — n/a. These appear to be FWHAI-side software interlocks (inferred from names only) new item (consider a single HA "controls enabled" switch for C4)
Reboot W, no confirm decorator but 400 without confirm=true (POST /api/reboot) no — — yes, 1721 not in HA (consequential; none of the three publish it)
Modbus TCP Server (aGate :502) on/off (DER comms: SunSpec / 2030.5) W (POST /api/der-comms, 409 to disable without confirm). R GET /api/der-comms no — WSet Enabled is related but different (inferred) yes, 1205, local-only (LOCAL_ONLY §1) not in HA (gateway-wide outage risk)
Raw / generic command W+confirm for writes (POST /api/raw, 428). POST /api/call/{cmd} W with no confirm no — — yes not in HA

Bridge-admin routes (gateways, sites, meters, utilities, tariffs, billing, schedules, HA instances, notify, MQTT admin, settings, backups, metrics) are bridge state, not device control, and are out of scope here. POST /api/admin/backup/{name}/restore is the only other _guard_consequential route.

§2 Sensors FWHAI or the Modbus Bridge publish that Direct MQTT lacks

Direct publishes 18 sensors (ENTITIES). Many of the rows below are already R in Direct REST. The gap is in publishing, not in reading.

  • Relays (FWHAI): Grid Relay 1/2, Solar PV Relay 1/2, Generator Relay, Black Start Relay, aPowerBox Relay, Battery Heater (binary_sensor).
  • Grid : Grid Status (FWHAI, enum), Grid Connection (MB), Grid Voltage, Grid Current, Frequency (MB), Voltage (FWHAI).
  • AC electricals (MB, SunSpec): Apparent Power (+L1), Reactive Power (+L1), Power Factor (+L1), Power L1, Current L1, Voltage L1.
  • Battery : Battery Current, Battery Temperature, Battery 1 Power / Voltage / Temperature, State of Health, Battery Health, Available Capacity, Total Capacity (MB). Battery Count, Batteries Online (FWHAI).
  • Flow breakdown (FWHAI): Battery Export to Grid, Solar Export to Grid, Solar Charging Battery, Grid Charging Battery.
  • Solar : Remote Solar PV1/PV2 (FWHAI), Solar Remote 1/2, Solar Proximal, PV Total Power (MB), MPPT Active Power, MPPT Status (FWHAI).
  • Smart circuits : per-circuit Power and Daily Energy (FWHAI).
  • Reserve : Active Reserve SOC (MB), Emergency Backup Reserved SOC (FWHAI).
  • Limits : Max Charge/Discharge Power or Rate (both).
  • Device / integration (FWHAI): Firmware Version, Model, Serial Number, Software Version (Cloud), Update Available, Grid Compliance Profile, Site Timezone, Last Restart, Startup Time, Integration Startup Time, MQTT Status, Data Provider, Control Source, Cloud Stale-Window Drops. Home Load Source, Operating Mode (diagnostic sensor), Control Mode, Inverter State (MB).
  • Network (FWHAI): WiFi Signal, Mobile Signal (dBm), Network Connection. METRICS_GAP_ANALYSIS: no local equivalent for signal strength found. Treat as not feasible locally.
  • Unconfirmed (MB): Ext 15016 (unconfirmed).

§3 Open questions (unverified)

  1. FWHAI 0.6.80 export has no SoC / power / mode entities. The 15 Oct 0.6.76 export of the same HA device had 13 more (State of Charge, Grid/Solar/Battery Power, Home Load, Operating Mode select and sensor, Ambient Temperature, Battery Current, Frequency, Available/Total Capacity, Grid Connection Status). Whether 0.6.80 dropped them, moved them to another HA device, or suppresses them when a Modbus Bridge is present (its "Data Provider" and "Control Source" sensors suggest provider selection) is unverified.
  2. The HA Operating Mode select bypasses confirm. REST POST /api/mode needs confirm=true, but the MQTT select writes with no confirm. That fits the owner rule only if mode change is not counted as "consequential". The code calls it consequential (_guard_consequential). This needs an owner decision. Read from code: publish/__init__.py:handle_command calls client.set_mode directly. It has no confirm and no _audit entry, so HA mode changes are missing from the Audit Trail. Whether client.set_mode itself enforces allow_writes was not checked.
  3. ~~POST /api/cloud/grid-status drove off-grid without confirm~~: fixed in 0.4.6 (GHSA-7jmj-vj3g-q2m3).
  4. Reserve-SoC write over Modbus (register 15508, "Self only, installer-unlocked") is a LOCAL_ONLY claim. It is not verified here, and the Modbus Bridge publishes both Self and TOU reserve numbers. Whether its TOU number actually applies is unverified.
  5. C4 power bounds. Modbus Bridge's Command Power max is 5000 W and FWHAI's Dispatch Power max is 5.0 kW. The plan requires sizing from the measured rating (/api/grid from SunSpec 702). Not checked whether either value matches this site's inverter.
  6. C4 coexistence. The Modbus Bridge and the Direct bridge would both drive WSet ("last command wins", owner decision). How either reports being overridden is unverified on hardware.
  7. Grid-limit local write (1701) is marked UNVERIFIED in code. Whether the aGate honours or discards it is unknown.
  8. Generator mode write is unexercised on generator hardware (409 guard).
  9. 1823 / 1825 (possible local power setpoint) are undecoded. No claim is made that they work.
  10. FWHAI lock switches: their semantics (software interlock in FWHAI vs a device setting) are inferred from names only.
  11. Every FWHAI and Modbus Bridge observation comes from one AU site, one firmware, one export pair. Treat them as candidates, not mappings.