Plan: Home Assistant controls over MQTT

Status: agreed (owner decisions in §4, 2026-10-16). Written 2026-10-16 after 0.4.4.

1. Where it stands (0.4.4)

21 entities per gateway: - 18 sensors, all with values since 0.4.3 (#96). - Controls: - an Operating Mode select (works); - three Smart Circuit switches. They accept on/off, but their state is always unknown: the poll never reads circuit state (1409).

There are no number entities (sliders), no buttons, and no limits.

The comparison of HA diagnostics from a live install (Direct 0.4.1 vs FWHAI 0.6.80 and Modbus Bridge 0.2.6 on the same aGate, 2026-10-16) shows what the other two bridges offer:

Control Modbus Bridge FWHAI Direct today How the bridge could do it
Smart circuit on/off with state — switch, state works switch, state unknown read 1409 each poll, or after each command
Reserve SoC (per mode) number 0–100 % number 0–100 % none local write is discarded by the aGate (1405, see API_COMPARISON.md), so only via the cloud provider (POST /api/cloud/reserve) when credentials exist
Grid export/import limit — number 0–100 kW plus "unlimited" switches none POST /api/grid/limits exists. It is an unverified local write, so it needs confirm
Battery command / dispatch select plus power, duration and target SoC dispatch action/power/duration/target none POST /api/dispatch and /api/battery/command exist
Off-grid — select none POST /api/offgrid (consequential, needs confirm)
Run status text — — raw number (1) publish run_status_desc, which the poll already has

2. Principles

  • Only writes verified on hardware become HA controls. An HA control that silently does nothing is worse than no control (the existing rule in publish/entities.py).
  • A control's state must come from a read, not from the last command. No control is published without a state source.
  • An HA control has no confirm dialog. So a consequential action (off-grid, dispatch, grid limits) is only exposed if the owner decides HA automations may do it unconfirmed.
  • New entities are additions, not identity changes. They can ship without the #92 migration, but each release covers one functional area (TEST_POLICY §1).

3. Releases, one area each, every one through G0–G3

Release Contents Gates beyond G0/G1
C1 Smart-circuit switch state: read 1409 in the poll's own session and publish circuit_N_on. Run status as text. G2 read-only: show the switch state follows the app; measure the poll time added
C2 Reserve SoC numbers (one per mode), published only when the cloud provider is configured. State from the provider's read. G2 write: plan, read back and the app showing the new value, restore the original
~~C3~~ Grid export/import limits: not exposed to HA (owner, 2026-10-16: no unconfirmed writes). They stay in the bridge UI. —
C4 Battery command, the same pattern as the Modbus Bridge and FWHAI (owner, 2026-10-16). See §3.1. G2 write: measured battery W against the command, revert timer, restore the mode; every status state seen on hardware
— Off-grid: not exposed to HA (owner, 2026-10-16) —

All of them: Modbus off on the real aGate, read-only by default, real hardware only on the owner's go-ahead in the session.

3.1 C4 battery command: the shape

  • select Battery Command: Not Active / Force Charge / Force Discharge / Force Standby / Release. Choosing a command is the action. It is the deliberate step that stands in for a confirm dialog.
  • number parameters, staged only. Changing one sends nothing to the aGate; it is used by the next command.
  • Power W, with Max Charge / Max Discharge sized from the measured inverter rating, not an assumed 5 kW;
  • Power %;
  • Duration (0 = no limit, which uses the bridge's revert timer);
  • Target SoC (0 = disabled).
  • Feedback (sensors), so the outcome is visible at once and an automation can act on it:
  • Command status: accepted → in progress → completed, or rejected (with the reason) or ended abnormally (with the reason: reverted by timer, overridden by the aGate or app, connection lost);
  • Active command, with the time it started and its remaining duration;
  • Last result: the measured battery W against the commanded W.
  • State comes from reads (the aGate's own state plus measured power), never from "the command was sent".

4. Decisions for the owner

  1. No control runs unconfirmed (owner, 2026-10-16). Grid limits and off-grid stay in the bridge UI. The C4 battery command is allowed because choosing the command is the explicit action (§3.1).
  2. C4 alongside the Modbus Bridge: last command wins (owner, 2026-10-16). The status sensor reports ended abnormally: overridden when another controller replaces this bridge's command.
  3. Off-grid as an HA control: no (from 1).
  4. Order: C1 → C2 → C4 (owner, 2026-10-16).