0.5.16 — 2026-10-26¶
Added¶
- User guide: shorter names in Home Assistant (#320). How to rename the bridge's device in Home Assistant so friendly names stop being cut to "FranklinWH Dir…" in history graphs and on phones. Entity IDs, history and automations are unchanged. With screenshots.
Fixed¶
-
Network tab: missing link data reads "not reported" (#302). When the aGate's answer had no network fields (as with the library Emulator), the tab showed every link as off, every interface as disabled and down, and Write safety as "single link". It now says "not reported", and Write safety says "unknown".
-
Grid & Inverter: the limits are shown and entered in kW (#312).
1701stores them in watts, so a stored 2000 showed as "2000 kW", and the dialog's "Custom kW" box wrote its number unchanged (2 would have set 2 W). The dialog no longer says the write is "confirmed ignored": with Debug Mode on (firmware V12R02B60D00, one test) it is stored; with it off, earlier firmware ignored it; enforcement is not yet tested. -
The worker-restart guard for an active force works (#175). It read a field the force status never returns, and it named a module it never imported, so it refused every guarded restart with "cannot determine dispatch state". It now refuses only while this bridge holds a force, and says which one. No worker uses this path yet; the dispatch watchdog is still thread-based.
- The Battery tab's charts refresh again (#317). The Trend chart, the Watch-live chart and the per-aPower cell charts stopped redrawing after their first draw: each refresh failed silently, so the chart froze while samples kept arriving. Switching metric redrew it once. The "updated" time above the cells now uses the site's time zone, like the chart.
- Battery Control forces through the Modbus client (this bridge) use franklinwh-modbus 0.10.1. The library now writes the force in watts (WSetMod=1 + WSet) and reads it back, instead of a percentage of 5000 W. On aGate firmware V12R02B60D00 the percentage form was refused above 10 % (500 W), as reported by the library. A refused write now says "Rejected by the aGate" at once. Charging is still refused on V12 (a firmware limit).
- A running force no longer shows as "Force Standby". With franklinwh-modbus 0.10.1 the force is held in watts (WSetMod=1 + WSet) and the percentage reads 0, which the bridge took for "standby". It now reads the field the aGate is using.