Skip to content

0.5.26 — 2026-11-03

Changed

  • franklinwh-modbus 0.10.1 → 0.13.0 for Battery Control. With 0.13.0, closing the Modbus client after a force, release, status check or ratings read closes the TCP socket. Before, the aGate's single Modbus session stayed held until garbage collection (franklinwh-modbus #138). The bridge sends forces in watts, which 0.11.0 left unchanged; the bridge uses none of the APIs that 0.11.0 and 0.13.0 change (percent forces, enum descriptions, check_state(), read_battery_status()).

Fixed

  • Demo mode's mock aGates start again (#427). docker-compose.demo.yml ran them on port 9000, which franklinwh-direct-connect-api 0.5.1 and later refuse (9000 is reserved for a real aGate and the official Gateway Emulator), so on a fresh build both restarted in a loop. They now run on 19000, under franklinwh-direct-connect emulate instead of the deprecated franklinwh-local name, and the demo bridge (FWH_PORT) reaches them there. Discover sweeps 9000 only, so it can't find them until #416.