Firmware map — what changed between two aGate releases¶
Status: WORKING DRAFT. This is the evidence as it stands, written down so the permanent version can be formulated from something real rather than from memory. Structure and wording are provisional; the measurements are not.
Scope: one aGate, one site. Everything here is the reference AU gateway (SyHdVersion
102 = AGT-R1V1-AU, "aGate X-01-AU"), single aPower. One site on one upgrade path is not a
release map for the product — it is two points on one device. Nothing here should be read
as "FranklinWH changed X in release Y".
| Earlier | IBG_VER V12R02B30D06_260304 — from a packet capture of the official app |
| Later | IBG_VER V12R02B60D00_260924 — from a read on 2026-10-31 |
| Apart | roughly six months |
| Hardware | identical. Nothing swapped between the two. |
1. The headline: the wire protocol version changed¶
This is the finding that explains the others. Both commands known to have changed their
key set did so across this boundary. If a key set varies, protocolVer is the field most
likely to predict it — more so than IBG_VER, which moves for reasons that do not affect
the wire.
Unverified: that protocolVer causes or reliably signals key-set changes. Two
commands across one upgrade is a correlation, not a rule. But it is the right field to
record and to test against.
Note this library's login sends minProtocolVer: "V1.00.00", and both firmwares accepted
it. There is no evidence the gateway refuses an old minimum.
2. Component versions — measured, complete for 1102¶
All from the 1102 login manifest, both sides. Serials excluded.
| Field | Earlier | Later | |
|---|---|---|---|
protocolVer |
V1.11.03 |
V1.12.02 |
changed |
IBG_VER |
V12R02B30D06_260304 |
V12R02B60D00_260924 |
changed |
APP_VER |
V12R00B07D04_260205 |
V12R00B16D00_260825 |
changed |
AWS_VER |
V12R00B06D04_260304 |
V12R00B15D00_260918 |
changed |
SL_VER |
V12R02B07D81 |
V12R02B12D00 |
changed |
BMS_VER |
['V11R50B03D00'] |
['V11R50B07D00'] |
changed |
DCDC_VER |
['V12R02B07D01'] |
['V12R02B10D00'] |
changed |
INV_VER |
['V12R02B09D03'] |
['V12R02B15D00'] |
changed |
FPGA_VER |
['V12R01B00D00'] |
['V12R01B00D00'] |
unchanged |
TH_VER |
['V11R02B01D00'] |
['V11R02B01D00'] |
unchanged |
BL_VER |
['V11R06B00D00'] |
['V11R06B00D00'] |
unchanged |
METER_VER |
V12R00B11D00 |
V12R00B11D00 |
unchanged |
SyHdVersion |
102 |
102 |
unchanged |
deviceType |
0 |
0 |
unchanged |
FHP_NUM |
1 |
1 |
unchanged |
threePhasePvPower |
0 |
0 |
unchanged |
Seven of eleven component versions moved; four did not. An OTA is not monolithic — the FPGA, thermal, bootloader and meter firmware stayed put while the controller, app, cloud agent, BMS, DC-DC and inverter all advanced.
SyHdVersion and deviceType did not move, which is consistent with them identifying
hardware rather than firmware. Two readings on one device; not proof.
Version string shape (inferred)¶
V{major}R{revision}B{build}D{patch} with an optional _{YYMMDD} build date:
V12R02B30D06_260304→ 2026-03-04;V12R02B60D00_260924→ 2026-09-24.- The date suffix appears only on
IBG_VER,APP_VERandAWS_VER— the component versions carry none. - Each component dates independently: at the earlier reading
APP_VERwas_260205whileIBG_VERandAWS_VERwere_260304.
Inferred from eight strings on one device. The D field is read as a patch number
because D81 → D00 alongside a build increase (B07 → B12) resembles a reset, but
nothing confirms the letters' meaning.
3. Key-set changes — two commands, both confirmed¶
1102 login manifest: 23 keys → 27 keys¶
Added (all per-unit lists, all reading a single element on this one-aPower site):
Removed: none. The change is purely additive.
PE_HW_VER reading [2] is interesting but not established: apower_models[2] in
franklinwh-cloud's catalogue is APR-05K13V1-AU, "aPower X-01-AU", which fits an AU
site. That PE_HW_VER indexes that table is inferred — aGate codes run 100–104 and
aPower codes 0–7, two separate spaces, and a hardware-revision field that happened to read
2 would look identical.
1701/1702 install profile: gridImportLimit absent → present¶
Earlier, 21 keys, no gridImportLimit, across four replies:
airSwitchCur electricSupply electricSys fhpRatePower genRatePower
gridExportEnable gridHardLimit gridPhaseConSet gridPhaseSeqSet gridSoftLimit
isPcsDischgEn isThreePhaseInstall kwRatePower ratedGridHz ratedGridVolt
solarInstallState solarInvManu solarInvRatePower opt result reason
Later: gridImportLimit present, reading -1. Partial evidence — that is a single
field reported by the Direct Connect Bridge session from a raw read on 2026-10-24, not a
full 1702 of my own. The rest of the later key set is unknown.
4. What this document cannot tell you¶
The comparison is complete for 1102 only. Both sides exist for exactly one command.
| Earlier firmware | Later firmware | |
|---|---|---|
1102 |
full | full |
1702 |
full (21 keys) | one key, third-party |
| the other 30 cmdTypes | full | nothing |
The capture holds 32 cmdTypes: 1101/1102, 1109/1110, 1111/1112, 1113/1114,
1117/1118, 1119/1120, 1301/1302, 1409/1410, 1411/1412, 1701/1702, 1723/1724,
1725/1726, 1727/1728, 1829/1830, 1901/1902, 1903/1904. For every one of those
except 1102 there is no later-firmware reading at all, so this document cannot say
whether they changed. Absence of a reported change is not evidence of no change.
Also absent from both sides: 1105/1106 device_check, 1709/1710 relay_status,
1831/1832 battery_modules, 1303/1304 energy_history, 1407/1408 tou_schedule,
1707/1708 ibg_run_status. Never exercised by the recorded app session.
5. What would complete it¶
One read-only session on the current firmware, capturing the same 32 cmdTypes the earlier
capture holds, would turn a one-command comparison into a real map. It needs the owner's
go-ahead and the aGate roll call, and it is a read throughout — no opt:1 anywhere.
Until then the honest summary is: the protocol version moved, four keys were added to the login manifest, one key was added to the install profile, and seven of eleven component firmwares advanced. Everything else is unobserved.
Evidence: a packet capture of the official app against the reference aGate
(V12R02B30D06_260304), and an owner-approved read-only login on 2026-10-31
(V12R02B60D00_260924). No serials, no site identifiers. The capture became readable only
after the pcap decoder was fixed — before that it decoded 12 frames of 335 and reported
success, so any earlier conclusion drawn from it is suspect.