Using franklinwh-direct-connect

A practical, end-to-end guide. For the wire format and command catalog see PROTOCOL.md; for a quick overview see the top-level README.


Install

Requires Python 3.10+. No runtime dependencies — standard library only.

From PyPI, which is all you need to use the library:

python3 -m venv .venv          # create a virtualenv
source .venv/bin/activate      # activate it  (Windows: .venv\Scripts\activate)
pip install franklinwh-direct-connect-api

franklinwh-direct-connect --version     # verify: prints "franklinwh-direct-connect 0.4.0"

From a checkout, if you want to hack on it or run the tests:

git clone https://github.com/david2069/franklinwh-direct-connect-api
cd franklinwh-direct-connect-api

python3 -m venv .venv
source .venv/bin/activate
pip install -e ".[test]"       # just "-e ." if you don't need pytest
pytest -m "not live"           # the offline suite; "live" tests need a real aGate

franklinwh-direct-connect is a console script installed onto your PATH — not a .py file in the repo. python franklinwh-direct-connect ... fails with can't open file. If the command isn't found, either activate the venv, call it by path (.venv/bin/franklinwh-direct-connect), or use the module form python -m franklinwh_direct_connect_api.

The three similar names: PyPI distribution franklinwh-direct-connect-api, import package franklinwh_direct_connect_api, CLI command franklinwh-direct-connect. The 0.3.x spellings (franklinwh_local, franklinwh-local, LocalClient) still work in 0.4.x and warn; see Migrating in the README.

First run, with no hardware

Three commands that need neither an aGate nor a network, as a check that the install works:

TCP 9000 is a reserved port

The emulator refuses to start on TCP 9000 and defaults to 19000. That port belongs to a real aGate and to the FranklinWH Gateway Emulator, the official and deliberately transparent emulator. This library's mock must stay distinguishable from a gateway — a mock left on 9000 once appeared in a LAN scan as 9000/sendMqtt CONFIRMED.

proxy is the exception and still listens on 0.0.0.0:9000. The rule is about what is behind the socket, not the number: the emulator answers with synthetic data, while the proxy relays every byte to a real aGate and never answers on its own behalf — so a client reaching it is talking to the gateway. Sitting on :9000 between the app and the device is exactly what the tool is for.

franklinwh-direct-connect catalog                            # the 70 known cmdTypes
franklinwh-direct-connect decode tests/fixtures/smoke.pcap   # decode a bundled capture
franklinwh-direct-connect emulate                            # a fake aGate on 19000; Ctrl-C to stop

(tests/fixtures/smoke.pcap ships in the git checkout, not the wheel.) With the emulator running, every live command below works against --host 127.0.0.1 — see Test without hardware.


Connect to the gateway (Direct Connection)

The aGate exposes the protocol on TCP/9000 on its own WiFi hotspot — the same "Direct Connect → Connect via aGate hotspot" path the FranklinWH mobile app uses.

  1. In the FranklinWH app, open Direct Connect and note the hotspot name, AP_<serial-suffix> (e.g. AP_F24170091).
  2. On your computer, join that WiFi network.
  3. The gateway is the hotspot's gateway IP — typically 10.100.1.1. Confirm/find it with the scanner:
franklinwh-direct-connect scan gateway          # auto-target the hotspot gateway
# 10.100.1.1: 9000/sendMqtt CONFIRMED (IBG_SN=<your gateway serial>)

You're now ready to issue commands against 10.100.1.1.

The app also lists a Bluetooth Direct Connect path. That's a separate (BLE) transport and is not implemented here — only the WiFi/TCP path.


CLI usage

Run franklinwh-direct-connect --help for the full list.

Command taxonomy

Commands fall into two groups — offline (work on files/the LAN, no aGate) and live (require --host/-i, connect to a real aGate over TCP 9000). Live commands are almost all read-only; only a handful write.

Group Commands Notes
Offline tooling decode, analyze, proxy, catalog, scan, emulate No --host needed
Live — composed views health, firmware, battery (alias bms), tou, energy_rollup, grid_profile, mode / offgrid / der_comms with no --set* Several cmdTypes per command, formatted for reading
Live — one per cmdType every name in franklinwh-direct-connect catalog — power_flow, energy_history, smart_circuits, battery_cells, network_interfaces, generator, the 25 grid_* blocks, … Read-only; all accept --watch/--count
Live — writes mode --set, offgrid --set, der_comms --set-modbus/--set-2030-5, reboot See the verification note below
Live — raw call <cmdType> Read by default; --data '{"opt":1,…}' writes any cmdType (no verification)

On 0.4.0 that is 87 subcommands: 16 purpose-built ones (plus the bms alias) and one per catalogued cmdType, generated from the catalog so the two cannot drift. Run franklinwh-direct-connect --help for the grouped list, or franklinwh-direct-connect <command> --help for one command.

How a write is verified differs per command, and result:0 is not success. The aGate acknowledges some frames it then discards, so most writers check something other than the ack:

Command What it checks
mode --set re-reads 1726 and prints current_id before→after
der_comms --set-modbus on\|off polls TCP :502 for up to 30 s for the expected state (apply is delayed by seconds and firmware-dependent; --and-reboot chains a reboot for firmware that needs one)
der_comms --set-2030-5 re-reads 1205 and reports enable / whether it has registered (lfdi)
reboot --wait polls :9000 down→up, and re-discovers the IP if it changed
offgrid --set nothing — it prints the aGate's result/reason only. Re-run offgrid to confirm it took
call … --data nothing at all

Reserved SoC (1405) is deliberately not exposed as a write: the aGate accepts it and silently discards it, because the cloud owns that value (see PROTOCOL.md and CLOUD_MAPPING §3).

Offline (no hardware)

franklinwh-direct-connect catalog                       # list known cmdType codes
franklinwh-direct-connect decode capture.pcap           # decode a capture
franklinwh-direct-connect decode capture.pcap --json    # ... as JSON

Discovery

franklinwh-direct-connect scan gateway                  # your default gateway only
franklinwh-direct-connect scan 10.100.1.0/24            # a whole subnet
franklinwh-direct-connect scan 10.0.0.1-10.0.0.50 --json
franklinwh-direct-connect scan 10.0.0.0/24 --no-probe   # open-port check only, no login

Detects TCP 9000 (sendMqtt) and TCP 502 (Modbus); for 9000 it confirms by performing the login handshake and reports the device IBG_SN.

scan gateway resolves your default gateway — the aGate when you are joined to its hotspot, but your own router otherwise. Trust the word CONFIRMED (the login handshake succeeded), not an open port: unrelated devices do listen on 9000.

Live reads

--host is required. Login happens automatically (pass --equip <serial> to skip it).

franklinwh-direct-connect --host 10.100.1.1 power_flow
franklinwh-direct-connect --host 10.100.1.1 smart_circuits
franklinwh-direct-connect --host 10.100.1.1 network_interfaces
franklinwh-direct-connect --host 10.100.1.1 call 1301 --data '{"opt":0}'   # any cmdType

franklinwh-direct-connect catalog lists every named read (and catalog --grep <text> searches them); the taxonomy above explains the groups. call <cmdType> issues any code directly, catalogued or not (default dataArea {"opt":0}).

Live writes

These command a real battery system. mode, offgrid and der_comms read when given no --set* flag, so the safe move is always to run the command bare first and keep the output. What each writer verifies is in the table under Command taxonomy.

# Operating mode (1727) — mode switch applies locally (verified)
franklinwh-direct-connect --host 10.100.1.1 mode                       # show current mode
franklinwh-direct-connect --host 10.100.1.1 mode --set self            # switch to Self-Consumption

# Off-grid (1723)
franklinwh-direct-connect --host 10.100.1.1 offgrid --set on --soc 20  # island, hold 20% floor
franklinwh-direct-connect --host 10.100.1.1 offgrid --set off          # reconnect

# DER comms (1205) — delayed apply; on older firmware ON needed a reboot to bind :502
franklinwh-direct-connect --host 10.100.1.1 der_comms                        # read both statuses
franklinwh-direct-connect --host 10.100.1.1 der_comms --set-modbus off       # polls :502 until it stops
franklinwh-direct-connect --host 10.100.1.1 der_comms --set-modbus on        # polls :502 until it binds
franklinwh-direct-connect --host 10.100.1.1 der_comms --set-modbus on --and-reboot  # ... and reboot if it doesn't
franklinwh-direct-connect --host 10.100.1.1 der_comms --set-2030-5 off       # disable IEEE 2030.5

# Reboot (1721) — warns if 4G is enabled; --wait verifies it returns (and re-discovers a new IP)
franklinwh-direct-connect --host 10.100.1.1 reboot --wait
franklinwh-direct-connect --host 10.100.1.1 firmware                         # firmware/version block

# Raw write of any cmdType (no verification — use with care)
franklinwh-direct-connect --host 10.100.1.1 call 1723 --data '{"opt":1,"offgridSet":0,"offgridSoc":5}'

Enabling IEEE 2030.5 / SEP2 (--set-2030-5 on) hands battery dispatch to a DERMS server and prompts to confirm. Reserved-SoC (1405) remains withheld — it is silently discarded locally (cloud-only). See PROTOCOL_DESIGN_REQUIREMENTS.md.

Watch / polling

franklinwh-direct-connect --host 10.100.1.1 power_flow --watch          # every 5s
franklinwh-direct-connect --host 10.100.1.1 power_flow --watch 10        # every 10s
franklinwh-direct-connect --host 10.100.1.1 power_flow --watch 5 --count 12

--watch [SECONDS] reuses one logged-in session and prints a line per poll (a friendly summary for power_flow, compact JSON otherwise). --count N stops after N samples; otherwise Ctrl-C.

Example output:

13:18:05  soc=66.5%  grid=19W  solar=-9W  batt=509W  load=519W  mode=Self-Consumption
13:18:10  soc=66.6%  grid=14W  solar=-7W  batt=502W  load=509W  mode=Self-Consumption

Library usage

The class is DirectConnectClient. LocalClient is kept as an alias of the same class for pre-0.4 code; new code should use the canonical name.

One-shot reads

from franklinwh_direct_connect_api import DirectConnectClient

with DirectConnectClient("10.100.1.1") as c:
    manifest = c.login()             # 1101 -> 1102; caches equipNo
    print(manifest["IBG_SN"], manifest["protocolVer"])

    flow = c.power_flow()            # 1301 -> 1302
    print(f"SoC {flow['soc']}%  load {flow['p_load']}W  battery {flow['p_fhp']}W")

    print(c.smart_circuits())        # 1409 -> 1410
    print(c.network_interfaces())    # 1117 -> 1118

Any command by number

with DirectConnectClient("10.100.1.1") as c:
    c.login()
    data = c.call(1201)              # time/location; default dataArea {"opt":0}
    data = c.call(1725, {"opt": 1})  # paged mode list with a custom dataArea

Low-level transport (full Frame objects)

from franklinwh_direct_connect_api import DirectConnectTransport

with DirectConnectTransport("10.100.1.1") as t:
    t.login()
    frame = t.request(1301, t.equip_no, {"opt": 0})
    print(frame.cmd_type, frame.snno, frame.verify(), frame.data_area)

Build / parse a single frame (no socket)

from franklinwh_direct_connect_api import encode_frame, decode_frame

wire  = encode_frame(1301, "FAKEGATE90FJ09J6H4F2", {"opt": 0})
frame = decode_frame(wire)
assert frame.verify()                # len + crc check

Writes from the library

The CLI exposes four writes; the library exposes more. franklinwh_direct_connect_api.WRITES is the machine-readable table (cmdType, opt, the fields each touches, and the note on how it was confirmed) — print it rather than trusting a summary.

Method cmdType How it verifies Status
set_mode(mode) 1727 opt:3 caller re-reads mode_list(); the CLI does this for you Applies locally (capture-confirmed 2026-06-19)
set_offgrid(on, soc) 1723 opt:1 none — returns the ack; re-read offgrid() yourself Applies locally
set_smart_circuit(circuit, on) 1409 opt:1 full-block RMW, then re-reads Sw{n}Mode; ok only on a matching read-back Hardware-verified 2026-09-14 (FW V12R02B30D06)
set_generator(**changes), set_generator_window, set_generator_exercise, set_generator_soc 1901 opt:1 full-block RMW, then re-reads every requested field Hardware-verified 2026-09-14 (FW V12R02B30D06)
set_der_comms(sunspec_modbus=…, sep2=…) 1205 opt:1 does not self-verify — confirm at the service level (:502, or status2030_5/lfdi) Delayed apply, firmware-dependent
set_circuit_schedule(circuit, slots, enabled) 1409 opt:1 re-reads, and sets discarded when the write was accepted but changed nothing Known no-op on FW V12R02B30D06 — the gateway ACKs and ignores it
reboot() 1721 opt:1 none in the library; the CLI polls :9000 Destructive — see the warning below
no method 1405 — Reserved SoC is cloud-owned: accepted locally and discarded. Deliberately not exposed
with DirectConnectClient("192.0.2.110") as c:
    c.login()
    c.set_mode("tou")                       # alias, full name, or site-specific id
    r = c.set_smart_circuit(2, on=True)     # {'ok': True, 'before': 0, 'after': 1, ...}
    if not r["ok"]:
        ...                                 # result:0 is NOT success — check ok

A write goes to a real battery system

set_offgrid islands the house. reboot() can make the aGate fail over to 4G and not come back on WiFi, which strands the local API until someone is on site — never reboot unattended. Enabling IEEE 2030.5 hands battery dispatch to a DERMS server. Read the block first, keep the prior_* values the writers return, and check ok rather than result.

Held sessions and threads

Every call used to open a TCP connection and log in before closing it again. A client can instead be held open across many commands (with still closes on exit):

c = DirectConnectClient("192.0.2.110")
c.connect()                  # idempotent
try:
    while True:
        c.ensure_session()   # connect + login only if needed; free once up
        sample = c.power_flow()
        ...
finally:
    c.close()                # idempotent; the client stays usable and will reconnect

c.connected                  # bool
c.connects                   # real TCP connects made — 1 on a healthy held session

connects is the diagnostic that matters: if it climbs, the session is not being reused. Verified against the in-process emulator — five ensure_session() + power_flow() rounds on one held client report connects == 1, and a close() followed by another call makes it 2.

The transport takes an RLock around a request and around login, so two threads sharing one client queue rather than interleaving frames on the socket. An idle policy is yours, not the library's — nothing closes a held session for you, and whether the aGate itself drops an idle TCP/9000 session, or expires a login, is unmeasured (see SESSION_DESIGN.md in the repo).


Test without hardware (emulator)

The emulator is a fake aGate. Responses are synthesised by a deterministic SyntheticSite — a plausible site (battery, aPowers, power flow, modes, smart circuits, energy history, the install profile and the site clock) derived from a seed, so no capture is bundled or needed. --seed, --serial and --units N (multi-aPower) shape it; --static turns the synthetic site off and answers from canned data only; Emulator(pcap=<path>) replays your own capture.

--tz-offset HOURS sets the site's UTC offset (fractional for the half-hour zones: 9.5). Omit it and each seed picks its own, which is useful colour for a single mock and wrong for several: gateways modelling ONE site must agree on the time of day, or anything deriving the site clock from a gateway gets a different answer per gateway.

franklinwh-direct-connect emulate --port 19001 --seed 1 --tz-offset 10
franklinwh-direct-connect emulate --port 19002 --seed 2 --tz-offset 10  # same site, same clock
franklinwh-direct-connect emulate
# in another shell:
franklinwh-direct-connect --host 127.0.0.1 power_flow
franklinwh-direct-connect scan 127.0.0.1      # finds and CONFIRMS it, like a real aGate

In Python (handy for tests):

from franklinwh_direct_connect_api import Emulator, DirectConnectClient

with Emulator("127.0.0.1", 0) as emu:        # port 0 = pick a free port
    with DirectConnectClient("127.0.0.1", emu.port) as c:
        c.login()
        print(c.power_flow())

The emulator proves your code, not the device

It serves what it was told to serve. A value it returns is not evidence of what a field means on real hardware, and a write it stores is not evidence the aGate keeps it. Coverage is partial, too — e.g. network_interfaces (1118) answers with the bare opt/result envelope rather than a modelled interface list (checked 2026-10-15). Use it for transport, parsing, CLI and integration work; take anything about device behaviour to the reference aGate.


Decode a packet capture

If you sniff the hotspot traffic (e.g. with Wireshark/tcpdump), decode it:

from franklinwh_direct_connect_api import iter_pcap_frames

for frame in iter_pcap_frames("capture.pcap"):
    print(frame.cmd_type, frame.name, frame.verify())
    print("   ", frame.data_area)

iter_pcap_frames handles TCP reassembly and per-frame seed detection, so both logins and normal frames decode transparently.


Extending the command catalog

When you observe a new cmdType, add it to franklinwh_direct_connect_api/catalog.py:

class Cmd(IntEnum):
    ...
    MY_NEW_READ = 1313          # response will be 1314

CATALOG[1313] = CmdInfo(1313, 1314, "my_new_read", "what it returns")

Then it's immediately usable via c.call(1313) and shows up in franklinwh-direct-connect catalog. To expose it as a named method, add a one-liner to client.py:

def my_new_read(self):
    return self.call(Cmd.MY_NEW_READ)

Energy history and rollups

The aGate stores daily energy history itself — a rolling window of roughly 105 days — and serves one day per request (energy_history, cmdType 1303):

franklinwh-direct-connect -i 192.0.2.110 energy_history --date 2026-09-10

96 quarter-hour points (rec_time, p_uti, p_gen, p_fhp, p_load), seven kwh_* daily totals, and per-tariff splits. For each channel, sharp + peak + flat + valley sums exactly to that channel's total.

Week / month / year rollups

The gateway has no rollup call — the cloud's week/month/year figures are computed cloud-side, and local dayType is echoed but ignored. energy_rollup does the same arithmetic locally, one request per day:

franklinwh-direct-connect -i 192.0.2.110 energy_rollup --period week
franklinwh-direct-connect -i 192.0.2.110 energy_rollup --period month --date 2026-08-15
franklinwh-direct-connect -i 192.0.2.110 energy_rollup --period total --json

Periods use the same numbering as the cloud's get_power_details(type=…): day=1, week=2, month=3, year=4, total=5.

Because retention is ~105 days, longer periods are necessarily partial. Every result reports its own coverage rather than presenting a short sum as a full period:

week 2026-09-07 .. 2026-09-11   5/5 days

channel           total     sharp      peak      flat    valley
---------------------------------------------------------------
kwh_sun        101.8760    0.0000    1.2743   99.9804    0.6211
kwh_fhp_chg     57.7883    0.0000    0.0000   57.5574    0.2310

--stop-after-empty N (default 5) stops walking back once N consecutive days come back empty — history is contiguous, so this avoids requesting a year of discarded dates.

Building interval history (bridge territory)

1303 cannot give you per-interval load or solar — its p_load series is a copy of p_fhp and there is no p_sun series at all (see CLOUD_MAPPING.md §3c). The live read 1301 reports both correctly, so the fix is to poll 1301 and store the samples.

That storage belongs in the bridge, not here. This library is the local leg only — protocol in, payloads out. Databases, retention, multi-gateway, REST and UI are the bridge's job (see BACKLOG.md EPIC-CLOUD-ALIGN).

What the library gives a poller:

from franklinwh_direct_connect_api import DirectConnectClient, energy

with DirectConnectClient("192.0.2.110") as c:
    c.login()
    s = c.power_flow()          # 1301 — poll this on your interval
    s["p_sun"], s["p_load"]     # both correct here, unlike 1303
    s["soc"], s["run_status"], s["mode"]

Relevant fields per sample: p_sun, p_gen, p_fhp, p_uti, p_load (watts), soc, t_amb, run_status, mode, the running daily kwh_* totals, and the live sharp/peak/flat/valley accumulators.

Sign conventions, matching the gateway's own daily totals: p_uti negative = export / positive = import; p_fhp positive = discharge / negative = charge.

Tariff-tier transitions

The tier arrays on 1301 are running accumulators that tick up through the day and reset at midnight. Whichever grew between two samples is the tier the device considered active — the only direct way to see when the boundary moves (BACKLOG DEF-1303-TIER-BASIS; daily totals show the split but never the timing):

energy.active_tier(sample, previous)        # -> "flat" | "peak" | ... | None
energy.tier_transitions(samples)            # -> [(ts, "flat", "peak"), ...]

Both are stateless helpers over payload dicts — sampling and persistence stay with the caller.

Battery Management (per-cell BMS)

franklinwh-direct-connect -i 192.0.2.110 battery              # one snapshot
franklinwh-direct-connect -i 192.0.2.110 battery --watch 2    # refresh every 2s, Ctrl-C to stop
franklinwh-direct-connect -i 192.0.2.110 battery --watch 5 --for 10m
franklinwh-direct-connect -i 192.0.2.110 battery --json > bms.json

Combines 1705 (per-cell voltages/temps, SoC/SoH), 1703 (grid and DC-bus rails), 1835 (states) and 1833 (serials/firmware) in one session — all local, no cloud, works on the Direct-Connect hotspot. bms is an alias.

🔬 Cell Telemetry (16 series)
              Highest: 3318 mV   (cell 13)
               Lowest: 3316 mV   (cell 1)
               Spread: 2 mV
           Temp Range: 20.5°C → 21.4°C   (cells 1–11)

  #1        #2        #3        #4        ...
  ↓3.316V    3.317V    3.317V    3.317V
   20.5°C    20.7°C    20.8°C    20.8°C

↓/↑ mark the lowest/highest cell and * the hottest; those positions are derived from the arrays, so nothing is lost versus the cloud's minVolPos/maxVolPos fields. Spread is coloured green ≤20 mV, amber ≤50 mV, red above.

Monitoring

flag effect
--watch [SECONDS] refresh every SECONDS (default 5)
--for DURATION stop after 90, 30s, 5m, 2h
--count N stop after N samples
--id N which aPower (from device_check devMap[].id)

Ctrl-C stops at any time. On a terminal the view repaints in place; piped or redirected output appends, so a log keeps every sample rather than a pile of escape codes. A dropped read during monitoring is reported and the session continues — this link is flaky by nature, so one bad poll should not end a ten-minute watch.

Colour auto-disables when output is not a terminal, and honours NO_COLOR; --no-colour forces plain text.

Local only. Thermal sensors (device/inverter/LLC/buck-boost), cell balancing state and MOS/fan/heater state are not on the local channel — they come from the cloud's get_bms_info() "Layer 2" payload. Rows that cannot be filled are omitted rather than shown blank. See CLOUD_MAPPING.md §3e.

TOU schedule

franklinwh-direct-connect -i 192.0.2.110 tou            # readable blocks
franklinwh-direct-connect -i 192.0.2.110 tou --bar      # with a 24-column day bar
franklinwh-direct-connect -i 192.0.2.110 tou --json

Decodes cmdType 1407's parallel arrays into ordered tariff blocks, and shows the gateway's own local time, timezone and DST flag (from 1201) so weekday/weekend is resolvable:

gateway time: 2026-09-11 17:54:08 Friday  (UTC+10, DST=on)

workday (5 blocks)
  00:00–00:30  tier 2 On-Peak
  00:30–02:00  tier 1 Mid-Peak
  02:00–04:00  tier 0 Off-Peak
  04:00–23:00  tier 1 Mid-Peak
  23:00–24:00  tier 2 On-Peak

Tariff only. The per-block dispatch action (Standby, Self-Consumption, Grid Export …) the app shows beside each block is not on the local channel — see CLOUD_MAPPING.md §3d.

Probing for undocumented cmdTypes

probe sweeps request codes against a live aGate and, for each one, tries several request payload shapes — not just the usual {"opt": 0}.

franklinwh-direct-connect -i 192.0.2.110 probe                       # uncatalogued odd codes
franklinwh-direct-connect -i 192.0.2.110 probe --range 1413-1699     # one block
franklinwh-direct-connect -i 192.0.2.110 probe --codes 1207,1209     # specific codes
franklinwh-direct-connect -i 192.0.2.110 probe --plain-only          # old single-shape sweep
franklinwh-direct-connect -i 192.0.2.110 probe --json > probe.json

Why the payload matrix matters

Every read this library issues is addressed to the aGate with {"opt": 0}. But not every read is gateway-addressed: the cloud API's per-cell BMS read sends its cmdType with {"fhpSn": "<aPower serial>", "type": 2} (and again with type: 3) — parameterised per battery. A code expecting that selector answers an {"opt": 0} probe with silence or an empty envelope, which looks exactly like "this code does not exist".

So probe tries, per code, in this order — and reports which shape worked:

  1. {"opt":0} — the plain gateway read.
  2. {"opt":0,"id":1}, {"opt":0,"id":2} — the device-index selector. These come before the serial shapes because id is the convention the local channel actually uses: 1703/1705/1833/1835 answer {"opt":0} with empty values and only fill them in when the request names a device (see CLOUD_MAPPING §3b). Finding 1705 per-cell telemetry turned on exactly this.
  3. {"fhpSn":SN}, {"fhpSn":SN,"type":2}, {"fhpSn":SN,"type":3}, {"opt":0,"fhpSn":SN} — the serial selector the cloud API uses, in case a code takes it.

Serials are auto-discovered from battery_modules (1831) and the login manifest (FHP_SN/BMS_SN); override with --serial SN (repeatable) or skip with --no-serials. --plain-only reverts to the old single-shape sweep.

By default the sweep stops at the first shape that responds — fastest when the question is "does this code exist?". Use --all-shapes when a code already answers {"opt":0} but looks thin: it tries every shape, prints each result side by side, and keeps the richest reply. Without it, a code that answers the very first shape never gets the selector shapes tried at all.

Custom payloads

--payload (repeatable) replaces the default matrix with your own shapes. %fhpSn% expands to each discovered serial:

franklinwh-direct-connect -i 192.0.2.110 probe --codes 1507 \
  --payload '{"opt":0}' \
  --payload '{"opt":0,"fhpSn":"%fhpSn%"}' \
  --payload '{"fhpSn":"%fhpSn%","type":4}'

A payload carrying opt set to anything but 0 is refused — opt=1 is the write convention, and probe is a read-only tool.

Reading the output

1507   HIT      [fhpSn,type]  17 keys: fhpSn, vol1, vol10, vol11, …  CELL-LIKE:vol*  <-- NEW
1509   envelope-only (responded, no data)
1511   timeout
  • HIT — the reply carried data beyond the opt/result/reason envelope.
  • <-- NEW — the code is not in catalog.CATALOG.
  • CELL-LIKE:<series> — ≥8 numeric values clustered in a plausible cell-voltage band (2.0–5.0 V or 2000–5000 mV). That is the signature of per-cell telemetry.
  • The closing summary counts how many hits needed an fhpSn selector — i.e. how many a plain opt=0 sweep would have missed.

The set of "already known" codes is derived from the catalog, so the swept range never goes stale as catalog.py grows.

Safety

Every shape probe sends is a read — opt=0 or a selector; it never sends opt=1 (the write convention). But it does send cmdTypes whose semantics are unknown, to a real battery system. Scope your sweeps with --codes/--range rather than blanket probing, and add confirmed finds to catalog.py so the next sweep skips them.


Troubleshooting

Symptom Likely cause / fix
python: can't open file '.../franklinwh-direct-connect' Drop the python — it's a console script, not a .py file. Just franklinwh-direct-connect ....
command not found: franklinwh-direct-connect Venv not activated (source .venv/bin/activate) or pip install -e . not run in it. Or use python -m franklinwh_direct_connect_api ....
No module named franklinwh_direct_connect_api Wrong interpreter — which python and pip -V should both point inside .venv.
scan gateway finds nothing Not joined to the AP_<serial> hotspot, or the gateway isn't the subnet .1 — try scan <subnet>/24.
Connection refused on 9000 Wrong host, or the aGate is not on this network. It answers on 9000 both on its own hotspot and on the LAN address it gets from your router — but a 4G failover takes it off the LAN entirely (observed; see DEF-WIFI-RECONNECT in BACKLOG.md), and then only the hotspot path works.
A live read returns empty arrays / result=1 reason=-1 That cmdType is addressed to a device, not the gateway: pass --id N (battery_cells, power_electronics, device_firmware, device_states). The keys look identical either way — only the values differ.
--help lists commands as ==SUPPRESS== A cosmetic bug (seen on Python 3.9–3.14): those per-cmdType subcommands are meant to be hidden from the positional list. They work normally; the grouped list in the same --help epilog is the real index, as is catalog.
TimeoutError on a read Increase --timeout; only one sendMqtt exchange happens at a time, so avoid concurrent clients.
call returns {"result": <non-zero>} The gateway rejected the request (bad opt/dataArea for that cmdType).
Decoded dataArea looks wrong File a capture — the seed auto-detects, but an unseen frame layout may need catalog work.

Security: the channel is plain TCP with keyless obfuscation. Anyone on the hotspot can read/forge frames, and payloads include WiFi credentials and location. Only use on networks you control.