Skip to content

FranklinWH MQTT Command Catalog

The sendMqtt gateway bridge endpoint (POST /hes-gateway/terminal/sendMqtt) is the legacy method FranklinWH used to relay highly-specific configuration and polling commands directly from the cloud to the physical aGate using numerical cmdType and parameter fields.

V2 API Discovery Warnings

Extensive architectural fuzzing has proven that modern V2 REST endpoints (like getDeviceRealTimeData or getHotSpotInfo/v2) are not 1:1 replacements for these MQTT relays. V2 endpoints drop over 99% of structural physics arrays (reducing massive voltage blocks to a single batterySoc cache value) to accelerate mobile-app load times. As a result, the sendMqtt payloads cataloged below remain the exclusive source of truth for deep hardware telemetry!

This ledger catalogs our library's Python mixin dependencies against known cmdType relays so we can effectively track hardware regressions.


Command Catalog

Below is the exhaustive index of numerical sendMqtt values mapped strictly to the Python wrapper methods that trigger them. Click any link in the Python Method column to view its formal definition in the API Reference.

cmdType MqttCmd Enum dataArea Sub-Type / Opt Python Method Payload Description
203 STATUS {"opt": 1} _status() High-level device component status polling. ⚠️ Legacy path — _status() is a private method not called by get_stats(). Normal polling uses getDeviceCompositeInfo REST GET (not this MQTT relay). See Transport Architecture.
211 POWER_AND_RELAYS {"type": 1} get_power_info() Full Gateway Electrical voltage/freq/relays
211 POWER_AND_RELAYS {"type": 2} get_bms_info() Detailed raw battery module info (Layer 1)
211 POWER_AND_RELAYS {"type": 3} get_bms_info() Detailed raw battery module info (Layer 2)
310 SMART_CIRCUIT_TOGGLE (Varies) set_smart_circuit_state() Toggle Smart Circuits (SwXMode) or limits
311 SMART_CIRCUIT_INFO {"opt": 0} read · {"opt": 1, ...} write get_smart_circuits_info() Smart Circuit naming, statuses and schedules. Read and write — there is no REST equivalent. A write echoes the whole Sw* block back with opt: 1, and SwNMsgType selects the kind of change: 1 = switch on/off, 2 = schedule/config edit. A write whose MsgType does not match its content is discarded silently with result: 0 — see DEF-311-CONFIG-WRITES-WRONG-MSGTYPE.
315 SYSTEM_CONTROL {"opt": 1, "paraType": 1, "reboot": 1} (none — not implemented) aGate reboot. ⛔ The same payload exposes reset, cleanUnlockAlarm, cleanLockAlarm, cleanAlarmFlag — never populate reset, it is almost certainly a factory reset.
317 NETWORK_INTERFACES {"opt": 0} get_network_info() Verbose eth/wifi interface IP and DHCP
327 AESTHETICS (Varies) led_light_settings() aPower RGB LED aesthetic limits
335 WIFI_SCAN {"wifi_ScanTime": 0} scan_wifi_networks() Trigger active 2.4/5GHz AP discovery
337 WIFI_CONFIG {"opt": 0} get_wifi_config() Connected SSID & local AP broadcast limits
339 CLOUD_CONNECTIVITY {"opt": 0} get_connection_status() AWS Cloud / Internet reachability checks
341 NETWORK_SWITCHES {"opt": 0} get_network_switches() Boolean flags for eth0/eth1/4G/wifi
353 ACCESSORY_LOADS {"opt": 0} get_accessories_power_info() SC / V2L / Generator current draw payloads

Response cmdType Mapping

The gateway answers request cmdType N with response N+1 — except STATUS, where 203 answers with 201. Do not assume N+1; use MqttResponse in franklinwh_cloud.models.

Request Response Confirmed occurrences
203 201 ⚠️ 780 — the one exception to the N+1 rule
211 212 137
311 312 283
315 316 2
317 318 484
327 328 418
335 336 39
337 338 388
339 340 67
341 342 38
353 354 1267

310 (SMART_CIRCUIT_TOGGLE) is absent deliberately: it has never been observed as a request in any capture, so its response code is unknown.

Read vs Write

Most commands use an opt flag (or optType for 317) to select direction: 0 reads, 1 writes. The library currently implements the read half of the network commands only.

The write payloads below are confirmed on the wire but not implemented — see Network Connectivity & WiFi Switching for the full analysis, safety preflight and phasing.

cmdType Write dataArea Status
337 {"opt":1,"wifi_SSID","wifi_Pw","ap_SSID","ap_Pw"} ✅ Confirmed. Sets WiFi credentials — and observed to move the gateway from 4G to WiFi on its own. ap_SSID/ap_Pw must be echoed from a preceding opt:0 read.
317 {"optType":1,"paraType":6,"commSetPara":{…},"num":N} ⚠️ Accepted (result:0) but only ever observed writing an unchanged currentNetType. num is the key count of commSetPara — compute it, never hardcode.
341 {"opt":1, …four switches…} ❌ Never observed. Shape inferred by analogy; must be validated no-op-first.
315 {"opt":1,"paraType":1,"reboot":1} ✅ Confirmed. Reboot only — never populate reset.

⚠️ A write ack (result:0) means the aGate accepted the config, not that it applied or associated successfully. A wrong WiFi password still returns result:0. Success can only be established by polling 317 afterwards.

Deprecation & Traceability

  • API V2 Fallacies: Previous hypotheses assumed modern V2 endpoints (like getHotSpotInfo/v2) replaced sendMqtt analogs. Our local matrix fuzzing verified this is false for integration developers requiring hardware physics arrays. The MqttCmd payloads listed above must be retained.
  • M713 Limitations: The LocRemCtl mode logic natively attempts to bypass these cloud relays altogether using Modbus TCP when users invoke local operations, which is why cataloging the sendMqtt trace is strictly tied to Remote-Only operations.

Unconfirmed: cmdType 387 / 389 (smart circuits)

Added 2026-09-14. Not implemented, and not observed here.

The third-party fork jkt628/franklinwh-python drives smart circuits with cmdType 387 (configuration) and 389 (status), where the 387 response carries a structured data["smartSwitch"][i]["schedule"] object. This library uses cmdType 311, whose schedule arrives as the flat parallel arrays SwNTime / SwNTimeEn / SwNTimeSet.

Evidence status — ASSUMED. Neither 387, 389 nor smartSwitch occurs anywhere in the 44-capture corpus (2025-02 → 2026-03, app 2.3.1 → 2.11.0), in which the highest observed cmdType is 354. A higher block with a richer schema is consistent with a later addition, but different hardware, a different market, or an error in the fork are equally consistent. Third-party code is a hypothesis, not a citation — see AP-14.

What would settle it: a capture from a current app session that touches Smart Circuits. If 387/389 are real and carry a structured schedule, they probably supersede 311 for this purpose and would resolve FEAT-SC-SCHEDULE-SETTER and DEF-SC-TIMESET-UNDECIPHERED without any guesswork about array layouts.