Generator & V2L API Reference

Scope: franklinwh_cloud mixin methods for the Generator Module and Vehicle-to-Load (V2L) accessories. Generator APIs are confirmed from live traffic. V2L control is speculative — see the clearly marked section below.


Generator Module

FranklinWH's Generator Module connects a standby petrol/diesel generator to the aGate system, enabling automatic start during grid outages or as a supplemental power source during off-grid operation.

Supported hardware:

Accessory Type SKU Notes
201 ACCY-GENV1-US V1 — enables V2L CarSW port on V1 Smart Circuits
203 ACCY-GENV2-US V2 — no V2L port (V2L built-in on V2 Smart Circuits)
301 ACCY-GENV1-AU AU V1 — no V2L capability on AU hardware

get_generator_info() — Confirmed

gen = await client.get_generator_info()

Endpoint: GET hes-gateway/terminal/selectIotGenerator

Returns: raw JSON dict from the aGate. Key fields observed:

Field Type Description
status int Current running state (mirrors genStat)
manuSw int Operating mode: 1 = Auto-schedule, 2 = Manual
opt int Option flag

Example:

gen = await client.get_generator_info()
print(gen)
# {'status': 0, 'manuSw': 2, 'opt': 1}

Note: Only call this if the generator module is installed. Check first:

snap = await client.discover()
if not snap.accessories.has_generator:
    print("No generator module installed")

Or via the accessories CLI:

franklinwh-cli accessories


set_generator_mode(mode) — Confirmed

result = await client.set_generator_mode(mode=1)

Endpoint: POST hes-gateway/terminal/updateIotGenerator

Parameters:

mode Behaviour
1 Auto-schedule (generator starts automatically on outage/threshold)
2 Manual (generator only runs when explicitly started)

Payload sent:

{"gatewayId": "10060006A0XXXXXXXXXX", "manuSw": 1, "opt": 1}

Important: This only toggles between Auto and Manual. Starting/stopping the generator physically and configuring auto-start thresholds is done in the FranklinWH app. There is no confirmed startGenerator / stopGenerator API endpoint in captured traffic.


✅ Generator Telemetry — get_stats() fields

All available without extra API calls, included in the standard stats poll:

stats = await client.get_stats()
cur = stats.current

print(cur.generator_production)  # float kW — live output
print(cur.generator_enabled)     # int — genEn flag (0/1)
print(cur.generator_status)      # int — genStat raw code

from franklinwh_cloud.const import GENERATOR_STATE
print(GENERATOR_STATE[cur.generator_status])
# "Standby / OFF" | "Running / ON" | "Cooldown" | "Fault"

Daily energy totals:

print(stats.totals.generator)          # float kWh — daily generator output
print(stats.totals.generator_load_kwh) # float — load served by generator


get_accessories_power_info(option=3) — Generator Live Power

gen_pwr = await client.get_accessories_power_info(option=3)
# → {"generator": {"power": 3.5, "voltage": 240.1, "current": 14.6, "frequency": 60.0}}

Source: MQTT cmdType 353 (CarSW + generator power data).


V2L — Vehicle-to-Load

V2L allows the aGate to power AC loads (e.g. tools, appliances, EV charging) directly from the battery, through the CarSW port on the Smart Circuit module.

Hardware compatibility:

Configuration V2L Capable? Notes
US V1 Smart Circuits (202) + Generator Module (201) ✅ Yes Via CarSW port on SC, enabled by Gen Module
US V2 Smart Circuits (204) ✅ Yes V2L built-in, no Generator Module needed
AU V1 Smart Circuits (302) ❌ No AU hardware has no V2L port
US V1 Smart Circuits only (no Gen Module) ❌ No CarSW port not available without Gen Module

Check eligibility in code:

snap = await client.discover()
print(snap.flags.v2l_eligible)  # bool
print(snap.flags.v2l_note)      # human-readable reason


✅ V2L Telemetry — All Confirmed

Real-time state

stats = await client.get_stats()
cur = stats.current

print(cur.v2l_enabled)   # int — runtimeData.v2lModeEnable (feature licence flag)
print(cur.v2l_status)    # int — runtimeData.v2lRunState
print(cur.v2l_use)       # float kW — CarSWPower (live output power)
print(cur.v2l_relay)     # int — cmdType 211 evRelayStat (contactor state)

from franklinwh_cloud.const import V2L_RUN_STATE
print(V2L_RUN_STATE[cur.v2l_status])
# 0 = "Disabled"
# 1 = "Standby"
# 2 = "Discharging / Active"
# 3 = "Fault"

Daily energy

print(stats.totals.v2l_export)   # float kWh — energy discharged through CarSW
print(stats.totals.v2l_import)   # float kWh — energy returned through CarSW

Live current/voltage (MQTT cmdType 353)

v2l = await client.get_accessories_power_info(option=2)
# → {
#     "v2l": {
#       "current":    12.3,   # A
#       "power":       2.8,   # kW
#       "imp_energy":  0.0,   # kWh
#       "exp_energy": 14.2    # kWh
#     }
#   }

Relay state (requires include_electrical=True)

stats = await client.get_stats(include_electrical=True)
print(stats.current.v2l_relay)
# cmdType 211 evRelayStat: 1=OPEN (contactor closed/active), 0=CLOSED

⚠️ set_v2l_mode(enable) — SPECULATIVE PLACEHOLDER

Status: SPECULATIVE — not verified on live V2L hardware.

This method is a placeholder based on analysis of the cmdType 311 Smart Circuit payload structure. It may or may not work. Do not use in production without live verification.

# ⚠️ SPECULATIVE — verify before production use
result = await client.set_v2l_mode(enable=True)   # Start V2L
result = await client.set_v2l_mode(enable=False)  # Stop V2L

Hypothesis

The CarSW port is Sw3 in the cmdType 311 Smart Circuit payload — the same mechanism used to control Smart Circuit 1 and 2. On a US V1 system with the Generator Module, modeChoose=3 in the 311 response indicates a 3-circuit configuration (Sw1 + Sw2 + Sw3/CarSW).

Expected 311 payload on a V2L-capable system:

{
  "Sw1Name": "Circuit 1",  "Sw1Mode": 1,
  "Sw2Name": "Circuit 2",  "Sw2Mode": 0,
  "Sw3Name": "V2L / Car",  "Sw3Mode": 1,   CarSW port
  "modeChoose": 3,                           3-circuit (Sw1+Sw2+Sw3/CarSW)
  "v2lModeEnable": 1,                        system V2L licence flag
  "v2lRunState": 2                           0=Disabled 1=Standby 2=Active 3=Fault
}

The speculative control write:

{
  "opt": 1,
  "Sw3Mode": 1,        1=ON (V2L active), 0=OFF
  "Sw3ProLoad": 0,     inverse of Sw3Mode (ProLoad is the "protected load" flag)
  "Sw3MsgType": 1      required write flag for circuit 3
}

Implementation

set_v2l_mode() calls _update_smart_circuit_config(circuit=3, ...) which: 1. Reads the current 311 state via get_smart_circuits_info() 2. Patches Sw3Mode and Sw3ProLoad 3. Writes back via _mqtt_send(cmdType=311, opt=1)

A WARNING level log is emitted at runtime to flag the speculative status.

Alternative hypothesis

A dedicated V2L endpoint (e.g. updateV2l or selectV2lMode) may exist that accepts v2lModeEnable directly, similar to how updateIotGenerator is separate from the Smart Circuit 311 path. This has not been observed in any captured mobile app traffic.

How to verify

If you have a US V1 aGate + Generator Module + Smart Circuits with V2L:

  1. Set up Charles Proxy or mitmproxy on your phone
  2. Open the FranklinWH app and navigate to the V2L / CarSW control
  3. Toggle V2L on and off
  4. Capture the raw POST payloads and compare against this hypothesis
  5. Open a GitHub issue with the captured payload: david2069/franklinwh-cloud

Fields to look for in the capture: - cmdType value (is it 311, or something new like 355/357?) - Presence of Sw3Mode vs a dedicated v2lModeEnable flag - Presence of modeChoose and its value - Any separate REST endpoint (not sendMqtt)

Prerequisites before calling

# 1. Hardware check
snap = await client.discover()
assert snap.flags.v2l_eligible, f"Not V2L capable: {snap.flags.v2l_note}"

# 2. Feature licence check
stats = await client.get_stats()
assert stats.current.v2l_enabled, "v2lModeEnable=0 — V2L not licensed on this gateway"

# 3. Off-grid check (V2L only works off-grid)
assert stats.current.grid_connection_state.value != "Connected", \
    "V2L requires off-grid mode (grid relay open)"

Field Reference — All V2L & Generator Stats Fields

stats.current.* Raw API field Source Type Notes
generator_production p_gen 203/runtimeData kW Live generator output
generator_enabled genEn 203/runtimeData int Feature enable flag
generator_status genStat 203/runtimeData int Use GENERATOR_STATE lookup
generator_relay main_sw[1] 203/runtimeData int 1=OPEN (connected)
v2l_enabled v2lModeEnable 203/runtimeData int System licence flag
v2l_status v2lRunState 203/runtimeData int Use V2L_RUN_STATE lookup
v2l_use CarSWPower 311/sw_data kW Live V2L output power
v2l_relay evRelayStat 211/result int V2L contactor state
v2l_export CarSWExpEnergy 311/sw_data kWh Daily V2L energy exported
v2l_import CarSWImpEnergy 311/sw_data kWh Daily V2L energy imported
stats.totals.* Raw API field Source Notes
generator kwh_gen 203/runtimeData Daily kWh
generator_load_kwh kwhGenLoad 203/runtimeData Load served
v2l_export CarSWExpEnergy 311/sw_data
v2l_import CarSWImpEnergy 311/sw_data