FranklinWH Modbus TCP Implementation Guide

Definitive reference for controlling FranklinWH aGate battery systems via Modbus TCP. Last verified: 2026-03-08 on aGate X (FW V10R01B04D00)


1. Connection

Host:    YOUR_AGATE_IP (default aGate IP)
Port:    502 (Modbus TCP)
Unit ID: 1 or 2 (both work, DA=1)
Base:    Address 1 (NOT standard 40000 for raw TCP)
Timeout: 10s recommended (WiFi can be slow)
from franklinwh_modbus import FranklinWHController
ctrl = FranklinWHController('YOUR_AGATE_IP')
ctrl.connect()  # Scans SunSpec models, probes extension writability

Models discovered: 1, 502, 701, 702, 703, 704, 705, 706, 707, 708, 709, 710, 711, 712, 713, 714, 715


2. What You CAN and CANNOT Do

┌─────────────────────────────────────────────────────┐
│ ✅ CAN DO (SunSpec M704):     ❌ CANNOT DO:         │
│  • Charge battery at Xw        • Change mode        │
│  • Discharge battery at Xw     • Set reserve %      │
│  • Set idle (standby)          • Switch to Backup   │
│  • Toggle power factor (PF)    • Set max power cap  │
│  • Read ALL registers          • Control ramp rate  │
│  • Auto-revert (software)      • Use heartbeat      │
└─────────────────────────────────────────────────────┘

Extension registers (15507-15509) require SPAN Modbus unlock via FranklinWH installer app. Without it, they are read-only.


3. Complete Writable Register Map

After exhaustive P1-P4 testing, only 5 of 48 M704 registers accept writes:

Register Address Type Works? What It Does
WSetEna 40318 enum16 Enable/disable battery power control
WSetMod 40319 enum16 Power mode (always set to 0)
WSetPct 40324 int16 Primary control — charge/discharge %
WSetRvrtTms 40327 uint32 ⚠️ Accepts value, countdown never activates
PFWInjEna 40298 enum16 Power factor enable (on by default)

Everything else — WMaxLimPct, VarSet, WRmp, ControllerHb, LocRemCtl — is either read-only (writes silently discarded) or unimplemented (returns None).


4. How to Control the Battery

Command Sequence (mandatory 4-step)

1. STOP:    WSetEna = 0               (disable control)
2. CONFIG:  WSetMod = 0, WSetPct = -X (set mode + power %)
3. ENABLE:  WSetEna = 1               (enable control)
4. VERIFY:  read WSetPct              (confirm value stuck)

Sign Convention: WSetPct is inverted on FranklinWH. Negative = charge, positive = discharge. The library handles this automatically.

Python API

from franklinwh_modbus.types import BatteryCommand, ControlMode

# Charge at 3000W
cmd = BatteryCommand(power_watts=3000, mode=ControlMode.LIMIT_ABS)
success, msg = ctrl.send_command(cmd)

# Charge with auto-revert after 1 hour (software timer)
ctrl.send_command(cmd, duration_s=3600)

# Check timer
ctrl.get_command_timer_status()  # {'active': True, 'interval_s': 3600}

# Stop / release control
ctrl.reset_control_state()

CLI

# Charge at 3000W (fire and forget — persists after CLI exits)
python3 tools/franklinwh_cli.py -i YOUR_AGATE_IP --charge 3000

# Charge with auto-revert
python3 tools/franklinwh_cli.py -i YOUR_AGATE_IP --charge 3000 --revert 3600

# Check status (won't kill active commands)
python3 tools/franklinwh_cli.py -i YOUR_AGATE_IP --status

# Stop
python3 tools/franklinwh_cli.py -i YOUR_AGATE_IP --stop

5. Key Hardware Quirks

5.1 The LocRemCtl Paradox

M715 LocRemCtl (addr 1089) is read-only, always "Local" (1). Per SunSpec 2, this should mean the DER rejects ALL writes. FranklinWH violates this — it selectively accepts power writes while ignoring lifecycle features:

Feature SunSpec 2 Expects FranklinWH Does
Power writes (WSetPct) ❌ Reject ✅ Accepts
Reversion countdown N/A ⚠️ Not verified with proper sequencing†
Controller heartbeat ❌ Reject ⚠️ Not verified with proper sequencing†
LocRemCtl write Allow ❌ Read-only

Impact: All lifecycle features (heartbeat, reversion timer) currently implemented in software. †Re-verification with proper SunSpec 6-phase sequencing pending — see SUNSPEC_DER_SEQUENCING_REFERENCE.md.

5.2 Command Persistence

Commands persist indefinitely after disconnect. The aGate holds the last WSetPct value until: - Another send_command() overwrites it - reset_control_state() sets WSetEna=0 - The aGate is power-cycled

There is no automatic timeout — hardware reversion (WSetRvrtTms) accepts values but never executes. Use the library's software timer (duration_s parameter).

5.3 Battery State Register Unreliable

M713 Sta is always 0 (OFF) regardless of actual state. Derive battery state from M714 DCW:

if dc_power < -50:   state = 'CHARGING'
elif dc_power > 50:  state = 'DISCHARGING'
else:                state = 'IDLE'

5.4 Sign Convention

Register Software Hardware
WSet Positive = Charge Positive = Charge
WSetPct Positive = Charge Negative = Charge

The library automatically inverts: m704.WSetPct.value = -pct_raw

5.5 WSet vs WSetPct Conflict

Writing to WSet (absolute watts) alongside WSetPct causes mode flickering on the aGate. The library uses only WSetPct. WSet is zeroed during reset_control_state().

5.6 Extension Registers & SPAN Modbus Unlock

Address Name Access Notes
15507 OnGridMode R (RW with SPAN) 0=Backup, 1=TOU, 2=Self-Consumption, 3=Manual
15508 SelfReserve R (RW with SPAN) Reserve SOC %
15509 TouReserve R (RW with SPAN) ⚠️ Always mirrors 15508 (firmware defect)

Write access to these registers requires the SPAN Modbus unlock — enabled by FranklinWH support for owners of SPAN Smart Panels. The aGate's Ethernet port passes through the SPAN Panel, which controls Modbus access.

Detecting SPAN Configuration

1. Network Scanner — detect SPAN Panel on the local network:

# Scan subnet for SPAN devices
python3 tools/network_scanner.py YOUR_SUBNET/24 --devices span -v

# Check specific IP
python3 tools/network_scanner.py YOUR_SPAN_IP --devices span -v

# mDNS discovery (no IP needed)
python3 tools/network_scanner.py --mdns --devices span
If a SPAN Panel is found alongside the aGate on the same network, extension registers are likely writable.

2. FranklinWH Cloud API — check spanFlag directly:

curl "https://energy.franklinwh.com/hes-gateway/terminal/span/getSpanSetting?gatewayId=YOUR_GATEWAY_ID"
{"code": 200, "result": {"spanFlag": 0}, "success": true}
- spanFlag: 0 → SPAN not configured (extensions read-only) - spanFlag: 1 → SPAN configured (extensions likely writable)

[!CAUTION] UNTESTED. We do not have a SPAN Panel (let alone one provisioned by FranklinWH) to verify this Cloud API endpoint or its effect on Modbus extension register writability. The above is based on API discovery only — actual behavior with spanFlag: 1 is unconfirmed.

3. Library auto-detection — the controller probes on connect():

ctrl.connect()
# Logs: "Extension registers: READ-ONLY (requires installer unlock for SPAN Modbus)"
# or:   "Extension registers: WRITABLE (SPAN Modbus enabled)"

[!NOTE] Community testing needed: We need a user with both SPAN Panel + aGate configured to verify that spanFlag: 1 enables write access to 15507-15509 via Modbus TCP.

Mode Control Tiers (Web App)

The admin console already defines three control tiers based on SPAN availability:

Tier Method Capability
⚡ Tier 1: SPAN Panel Direct Modbus register writes Full mode/reserve control (Phase 4)
☁️ Tier 2: Cloud Bypass Mode changes via Cloud API Mode control, data stays Modbus
📖 Tier 3: Read-Only View only No control

TODO: SPAN detection + Mode Control Tier selection should move from MQTT Admin to a Setup Wizard — it's a one-time configuration decision, not an MQTT setting.

5.7 PFWInjEna (Power Factor)

PFWInjEna (40298) is enabled by default (=1) and writable: - Enabled (=1): PF ≈ unity (-1 raw, SF -3) - Disabled (=0): PF = 0.003 (essentially no correction) - Do not leave disabled — it controls the aGate's default PF correction

5.8 SunSpec2 Library Quirks

The sunspec2 Python client remaps addresses internally. Extension registers (15000+, 15500+) must be read via raw Modbus TCP socket, not sunspec2.client.read():

import struct
sock = ctrl.dev.client.socket
req = struct.pack('>HHHBBHH', 0, 0, 6, unit_id, 3, addr, count)
sock.sendall(req)
resp = sock.recv(256)

5.9 M715 Address Space

M715 registers are only accessible at base-1 addresses via raw TCP. Base-40000 addresses (41087+) return ILLEGAL_DATA_ADDRESS.


6. Software vs Hardware Features

Feature Hardware Software (Library)
Charge/Discharge ✅ M704 WSetPct send_command()
Auto-Revert Timer ❌ WSetRvrtTms broken duration_s param
Heartbeat ❌ ControllerHb ignored ❌ Not implemented
SoC Ramp ❌ WRmp unimplemented --soc-ramp-window
Battery State ❌ M713.Sta always 0 ✅ Derived from M714 DCW
Conflict Detection N/A check_state()
Mode Control ❌ Extensions read-only ⚠️ Virtual modes (power-only)

7. Reading System State

# Battery
bat = ctrl.read_battery_status()
# → soc, dc_power, dc_voltage, temperature, battery_state

# Solar + Grid + Load
solar = ctrl.read_solar_production()
grid  = ctrl.read_grid_status()

# Control status
ctl = ctrl.read_control_status()
# → wset_enabled, wset_pct, wset_watts

# Native mode (aGate's cloud setting)
mode = ctrl.read_native_mode()
# → mode_name, self_reserve_pct, tou_reserve_pct

# Health check (zombie state detection)
h = ctrl.healthcheck()
# → healthy, message, recommendations

Document What It Covers
DER_CONTROL_REFERENCE.md Full register map — all 48 M704 + 6 M715 fields
FRANKLINWH_SUNSPEC_QUIRKS.md Detailed quirk analysis (LocRemCtl, M713, extensions)
ORCHESTRATION_AND_CONTROL.md Command sequences, SoC ramping, entry points
VERIFICATION_BASELINE.md Full register dump + cross-verification

Test Evidence

Test Result Evidence
P1: Heartbeat ❌ Confirmed non-functional (6-phase re-test) tests/results/2026-03-08_p1_control_tests.md
P1: WSetRvrtTms WORKS (60s accepted, countdown active) Re-tested 2026-03-13 with proper sequencing
P2: WMaxLimPct ❌ Confirmed non-functional (enable silently discarded) tests/results/2026-03-08_p2p4_control_tests.md
P3: VarSet ❌ Confirmed non-functional (VarSetEna silently discarded) Re-tested 2026-03-13 with 6-phase protocol
PCS WChaRteMax/WDisChaRteMax ❌ Confirmed 0xFFFF (not writable) tests/results/2026-03-13_pcs_charge_rate_write_probe.md
P4: WRmp ❌ Unimplemented Same file
PFWInjEna ✅ Writable Same file
Extension write-probe ❌ Read-only tests/results/2026-03-08_extension_write_probe.md

Device: FranklinWH aGate X (SN: XXXXXXXXXXXXXXXXXXXX, FW: V10R01B04D00) Last Updated: 2026-03-09